XC6802A42XER-G Torex Semiconductor Ltd, XC6802A42XER-G Datasheet - Page 5

55T4030

XC6802A42XER-G

Manufacturer Part Number
XC6802A42XER-G
Description
55T4030
Manufacturer
Torex Semiconductor Ltd
Datasheet

Specifications of XC6802A42XER-G

Battery Type
Li-Ion
Input Voltage
6V
Battery Charge Voltage
2.9V
Charge Current Max
800mA
Battery Ic Case Style
USP-6C
No. Of Pins
6
No. Of Series Cells
1
Operating Temperature Range
-40°C
Rohs Compliant
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XC6802A42XER-G
Manufacturer:
SAMSUNG
Quantity:
12 000
Part Number:
XC6802A42XER-G
Manufacturer:
TOREX
Quantity:
12 000
Part Number:
XC6802A42XER-G
Manufacturer:
TOREX
Quantity:
20 000
■OPERATIONAL EXPLANATION
<Charge Cycle>
If the BAT pin voltage is less than 2.9V, the charger enters trickle charge mode. In this mode, a safe battery charge is possible
because approximately only 1/10 of the charge current which was set by the I
pin voltage rises above 2.9V, the charger enters constant-current mode (CC mode) and the battery is charged by the
programmed charge current. When the BAT pin voltage reaches 4.2V, the charger enters constant-voltage mode (CV mode)
automatically. After this, the charge current starts to drop and when it reaches a level which is 1/10 of the programmed charge
current, the charge terminates.
<Setting Charge Current>
The charge current can be set by connecting a resistor between the I
is 1000 times the current out of the I
I
However I
<Charge Termination>
The battery charge is terminated when the charge current decreases to 1/10 of the full charging level after the battery pin
voltage reaches a float voltage. An internal comparator monitors the I
the comparator monitors the I
time), the IC enters stand-by mode. A driver transistor turns off during the stand-by mode. In this state, a failure detection
circuit and a monitoring circuit of the battery pin voltage operates and supply current is reduced to 10μA.
<Automatic Recharge>
In stand-by mode battery voltage falls. When the voltage level at the battery pin drops to 4.05V or less, the charge cycle
automatically re-starts after a delay of 2ms. As such, no external activation control is needed.
BAT
= (V
ISEN
BAT
/ R
≦800mA
SEN
) x 1000 (V
ISEN
SEN
pin voltage is less than 100mV (charge termination detect) for 1ms (charge termination detect
= 1.0V: Current sense pin voltage)
SEN
pin. Therefore, the charge current, I
SEN
SEN
pin and the V
pin voltage to detect the charge termination. When
BAT
SEN
, is calculated by the following equations:
pin, is supplied to the battery. When the BAT
SS
pin. The battery charge current, I
XC6802
Series
5/18
BAT
,