M28W160ECB70ZB6 Micron Technology Inc, M28W160ECB70ZB6 Datasheet - Page 13

no-image

M28W160ECB70ZB6

Manufacturer Part Number
M28W160ECB70ZB6
Description
Manufacturer
Micron Technology Inc
Datasheet

Specifications of M28W160ECB70ZB6

Cell Type
NOR
Density
16Mb
Access Time (max)
70ns
Interface Type
Parallel
Boot Type
Bottom
Address Bus
20b
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
TFBGA
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
16b
Number Of Words
1M
Supply Current
18mA
Mounting
Surface Mount
Pin Count
46
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M28W160ECB70ZB6
Manufacturer:
ST
0
Part Number:
M28W160ECB70ZB6
Manufacturer:
ST
Quantity:
20 000
Part Number:
M28W160ECB70ZB6 L
Manufacturer:
ST
0
Part Number:
M28W160ECB70ZB6E
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
M28W160ECB70ZB6E
Manufacturer:
ST
0
Part Number:
M28W160ECB70ZB6L
Manufacturer:
ST
0
Register error. The protection of the Protection
Register and/or the Security Block is not revers-
ible.
The Protection Register Program cannot be sus-
pended.
23., Protection Register Program Flowchart and
Pseudo
tection Register Program command.
Block Lock Command
The Block Lock command is used to lock a block
and prevent Program or Erase operations from
changing the data in it. All blocks are locked at
power-up or reset.
Two Bus Write cycles are required to issue the
Block Lock command.
The lock status can be monitored for each block
using the Read Electronic Signature command.
Table 9.
a Block Lock command.
The Block Lock bits are volatile, once set they re-
main set until a hardware reset or power-down/
power-up. They are cleared by a Blocks Unlock
command. Refer to the section, Block Locking, for
a detailed explanation.
Block Unlock Command
The Blocks Unlock command is used to unlock a
block, allowing the block to be programmed or
The first bus cycle sets up the Block Lock
command.
The second Bus Write cycle latches the block
address.
Code, for the flowchart for using the Pro-
shows the protection status after issuing
See
APPENDIX
C.,
Figure
erased. Two Bus Write cycles are required to is-
sue the Blocks Unlock command.
The lock status can be monitored for each block
using the Read Electronic Signature command.
Table 9.
a Block Unlock command. Refer to the section,
Block Locking, for a detailed explanation.
Block Lock-Down Command
A locked block cannot be Programmed or Erased,
or have its protection status changed when WP is
low, V
function is disabled and the locked blocks can be
individually unlocked by the Block Unlock com-
mand.
Two Bus Write cycles are required to issue the
Block Lock-Down command.
The lock status can be monitored for each block
using the Read Electronic Signature command.
Locked-Down blocks revert to the locked (and not
locked-down) state when the device is reset on
power-down.
after issuing a Block Lock-Down command. Refer
to the section, Block Locking, for a detailed expla-
nation.
The first bus cycle sets up the Block Unlock
command.
The second Bus Write cycle latches the block
address.
The first bus cycle sets up the Block Lock
command.
The second Bus Write cycle latches the block
address.
IL
. When WP is high, V
shows the protection status after issuing
Table 9.
M28W160ECT, M28W160ECB
shows the protection status
IH,
the Lock-Down
13/50

Related parts for M28W160ECB70ZB6