M29W320ET70N6 Micron Technology Inc, M29W320ET70N6 Datasheet - Page 22

no-image

M29W320ET70N6

Manufacturer Part Number
M29W320ET70N6
Description
Manufacturer
Micron Technology Inc
Datasheet

Specifications of M29W320ET70N6

Cell Type
NOR
Density
32Mb
Access Time (max)
70ns
Interface Type
Parallel
Boot Type
Top
Address Bus
22/21Bit
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
TSOP
Program/erase Volt (typ)
2.7 to 3.6/12V
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8/16Bit
Number Of Words
4M/2M
Supply Current
10mA
Mounting
Surface Mount
Pin Count
48
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W320ET70N6
Manufacturer:
STMI
Quantity:
8
Part Number:
M29W320ET70N6
Manufacturer:
HIT
Quantity:
237
Part Number:
M29W320ET70N6
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29W320ET70N6
Manufacturer:
ST
0
Part Number:
M29W320ET70N6
Manufacturer:
ST
Quantity:
20 000
Part Number:
M29W320ET70N6E
Manufacturer:
MICRON
Quantity:
15 600
Part Number:
M29W320ET70N6E
Manufacturer:
Numonyx
Quantity:
23 040
Part Number:
M29W320ET70N6E
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29W320ET70N6E
Manufacturer:
ST
0
Part Number:
M29W320ET70N6E
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
M29W320ET70N6E
Quantity:
10 000
Part Number:
M29W320ET70N6H
Manufacturer:
ST
0
4.3
4.4
22/65
Read CFI Query command
The Read CFI Query Command is used to read data from the Common Flash Interface
(CFI) memory Area. This command is valid when the device is in the Read Array mode, or
when the device is in Auto Select mode.
One Bus Write cycle is required to issue the Read CFI Query Command. Once the
command is issued subsequent Bus Read operations read from the Common Flash
Interface memory Area.
The Read/Reset command must be issued to return the device to the previous mode (the
Read Array mode or Auto Select mode). A second Read/Reset command would be needed
if the device is to be put in the Read Array mode from Auto Select mode.
See
Table 27
Interface (CFI) memory area.
Program command
The Program command can be used to program a value to one address in the memory
array at a time. The command requires four Bus Write operations, the final write operation
latches the address and data, and starts the Program/Erase Controller.
If the address falls in a protected block then the Program command is ignored, the data
remains unchanged. The Status register is never read and no error condition is given.
During the program operation the memory will ignore all commands. It is not possible to
issue any command to abort or pause the operation. After programming has started, Bus
Read operations output the Status register content. See
details. Typical program times are given in
After the program operation has completed the memory will return to the Read mode, unless
an error has occurred. When an error occurs Bus Read operations will continue to output
the Status register. A Read/Reset command must be issued to reset the error condition and
return to Read mode.
Note that the Program command cannot change a bit set at ’0’ back to ’1’. One of the Erase
Commands must be used to set all the bits in a block or in the whole memory from ’0’ to ’1’.
Appendix B: Common Flash Interface
and
Table 28
for details on the information contained in the Common Flash
(CFI),
Table 6
Table
23,
Section 5: Status register
Table
24,
Table
25,
Table
for more
26,

Related parts for M29W320ET70N6