LC05-6 Semtech, LC05-6 Datasheet - Page 4

LC05-6

Manufacturer Part Number
LC05-6
Description
Manufacturer
Semtech
Datasheet

Specifications of LC05-6

Number Of Elements
4
Polarity
Uni-Directional
Package Type
SOIC
Operating Temperature Classification
Military
Reverse Breakdown Voltage
6.8V
Clamping Voltage
20V
Reverse Stand-off Voltage
6V
Leakage Current (max)
15uA
Peak Pulse Current
100A
Peak Pulse Power Dissipation
2000W
Test Current (it)
1mA
Operating Temp Range
-55C to 125C
Mounting
Surface Mount
Pin Count
16
Lead Free Status / Rohs Status
Not Compliant
Device Connection Options for Protection of Two
High-Speed Line Pairs
The LC05-6 is designed to protect four high-speed data
lines (two differential pairs) from transient over-volt-
ages which result from lightning and ESD. Protection
of two line pairs is achieved by connecting the device
as follows: Pins 1-4 are connected to line 1 of the first
pair (i.e. Tip 1) and pins 13-16 are connected to line 2
of the first pair (i.e. Ring 1). Pins 5-8 are connected to
line 1 of the second pair (i.e. Tip 2) and pins 9-12 are
connected to line 2 of the second pair (i.e. Ring 2). All
pins should be connected for best results. Minimize
parasitic inductance in the protection circuit path by
keeping the trace length between the protected line
and the LC05-6 as short as possible.
T1/E1 Linecard Protection
A typical T1/E1 linecard protection circuit is shown in
Figure 2. The LC05-6 is connected between Tip & Ring
on the transmit and receive line pairs. It provides
protection to metallic (line-to-line) lightning and ESD
surges. It is designed to meet the intra-building re-
quirements of Bellcore GR-1089. This design takes
advantage of the isolation of the transformer to
suppress common mode surges. To complete the
protection circuit, the SRDA05-4 (or SRDA3.3-4 for
3.3V supplies) is employed as the IC side protection
element. This device helps prevent the transceiver
from latching up by providing fine clamping of tran-
sients that are coupled through the transformer.
PROTECTION PRODUCTS
Applications Information
2003 Semtech Corp.
4
Figure 1 - Connection for Differential (Line-to-Line)
TIP 1
TIP 2
Protection of two Tip/Ring Line Pairs
LC05-06
www.semtech.com
RING 1
RING 2

Related parts for LC05-6