CY6264-55SNC Cypress Semiconductor Corp, CY6264-55SNC Datasheet - Page 2

CY6264-55SNC

Manufacturer Part Number
CY6264-55SNC
Description
Manufacturer
Cypress Semiconductor Corp
Datasheet

Specifications of CY6264-55SNC

Density
64Kb
Access Time (max)
55ns
Sync/async
Asynchronous
Architecture
Not Required
Clock Freq (max)
Not RequiredMHz
Operating Supply Voltage (typ)
5V
Address Bus
13b
Package Type
SNC N
Operating Temp Range
0C to 70C
Number Of Ports
1
Supply Current
100mA
Operating Supply Voltage (min)
4.5V
Operating Supply Voltage (max)
5.5V
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
28
Word Size
8b
Number Of Words
8K
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CY6264-55SNC
Manufacturer:
CY
Quantity:
69
Part Number:
CY6264-55SNC
Quantity:
200
Company:
Part Number:
CY6264-55SNC
Quantity:
10
Document #: 001-02367 Rev. **
Selection Guide
Maximum Ratings
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Storage Temperature ................................. –65°C to +150°C
Ambient Temperature with
Power Applied............................................. –55°C to +125°C
Supply Voltage to Ground Potential ............... –0.5V to +7.0V
DC Voltage Applied to Outputs
in High Z State
DC Input Voltage
Electrical Characteristics
Maximum Access Time
Maximum Operating Current
Maximum Standby Current
Shaded areas contain advance information.
V
V
V
V
I
I
I
I
I
I
Shaded areas contain advance information.
Notes:
Parameter
IX
OZ
OS
CC
SB1
SB2
1. Minimum voltage is equal to–3.0V for pulse durations less than 30 ns.
2. Not more than 1 output should be shorted at one time. Duration of the short circuit should not exceed 30 seconds.
OH
OL
IH
IL
Output HIGH Voltage
Output LOW Voltage
Input HIGH Voltage
Input LOW Voltage
Input Load Current
Output Leakage
Current
Output Short
Circuit Current
V
Supply Current
Automatic CE
Power–Down Current
Automatic CE
Power–Down Current
[1]
CC
[1]
............................................ –0.5V to +7.0V
Operating
Description
......................................... –0.5V to +7.0V
1
1
[2]
[1]
Over the Operating Range
V
V
GND < V
GND < V
Output Disabled
V
V
V
I
Max. V
Min. Duty Cycle=100%
Max. V
V
OUT
CC
CC
CC
OUT
CC
IN
> V
= Max.,
= Min., I
= Min., I
= Max.,
= 0 mA
= GND
CC
CC
CC
I
I
, CE
, CE
< V
< V
– 0.3V or V
Test Conditions
OH
OL
Commercial
Industrial
Commercial
Industrial
CC
CC
1
1
> V
> V
= 8.0 mA
,
= –4.0 mA
IH,
CC
IN
– 0.3V,
< 0.3V
Output Current into Outputs (LOW)............................. 20 mA
Static Discharge Voltage........................................... >2001V
(per MIL-STD-883, Method 3015)
Latch-Up Current .................................................... >200 mA
Operating Range
Commercial
Industrial
Com’l
Ind’l
Com’l
Ind’l
Com’l
Ind’l
Range
CY6264-55
20/15
100
55
Min.
–0.5
2.4
2.2
–5
–5
6264-55
–40
Max.
–300
V
100
Temperature
0
0.4
0.8
+5
+5
20
15
CC
°
Ambient
C to +70
°
CY6264-70
C to +85
20/15
100
200
70
30
Min.
–0.5
2.4
2.2
–5
–5
°
C
°
6264-70
C
Max.
–300
V
100
200
0.4
0.8
+5
+5
20
40
15
30
CC
CY6264
Page 2 of 10
5V ± 10%
Unit
mA
mA
V
ns
CC
Unit
mA
mA
mA
mA
µA
µA
V
V
V
V
[+] Feedback

Related parts for CY6264-55SNC