CY2308SC-2T Cypress Semiconductor Corp, CY2308SC-2T Datasheet - Page 6

CY2308SC-2T

Manufacturer Part Number
CY2308SC-2T
Description
Manufacturer
Cypress Semiconductor Corp
Type
Zero Delay PLL Clock Driverr
Datasheet

Specifications of CY2308SC-2T

Number Of Elements
1
Supply Current
45mA
Operating Supply Voltage (typ)
3.3V
Operating Temp Range
0C to 70C
Package Type
SOIC
Output Frequency Range
10 to 133.3MHz
Operating Supply Voltage (min)
3V
Operating Supply Voltage (max)
3.6V
Operating Temperature Classification
Commercial
Pin Count
16
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CY2308SC-2T
Manufacturer:
TMTE
Quantity:
139
Part Number:
CY2308SC-2T
Manufacturer:
CY
Quantity:
2 179
Part Number:
CY2308SC-2T
Manufacturer:
CY
Quantity:
4 363
Part Number:
CY2308SC-2T
Manufacturer:
CYPRESS/赛普拉斯
Quantity:
20 000
Company:
Part Number:
CY2308SC-2T
Quantity:
1 643
Operating Conditions for Industrial Temperature Devices
Electrical Characteristics for Industrial Temperature Devices
Switching Characteristics for Industrial Temperature Devices
Document Number: 38-07146 Rev. *H
V
T
C
C
t
V
V
I
I
V
V
I
I
t
t
t
t
t
t
t
t
t
t
PU
IL
IH
DD
DD
1
1
1
PD
PD
3
3
3
4
4
A
DD
IL
IH
OL
OH
L
IN
Parameter
Parameter
Parameter
(PD mode)
[8]
Output Frequency
Output Frequency
Output Frequency
Duty Cycle
(–1, –2, –3, –4, –1H, –5H)
Duty Cycle
(–1, –2, –3, –4, –1H, –5H)
Rise Time
(–1, –2, –3, –4)
Rise Time
(–1, –2, –3, –4)
Rise Time
(–1H, –5H)
Fall Time
(–1, –2, –3, –4)
Fall Time
(–1, –2, –3, –4)
Supply Voltage
Operating Temperature (Ambient Temperature)
Load Capacitance, below 100 MHz
Load Capacitance, from 100 MHz to 133 MHz
Input Capacitance
Power up time for all V
ramps must be monotonic)
Input LOW Voltage
Input HIGH Voltage
Input LOW Current
Input HIGH Current
Output LOW Voltage
Output HIGH Voltage
Power Down Supply Current
Supply Current
Description
[7, 8]
[7, 8]
[7, 8]
[7, 8]
[7, 8]
[7, 8]
[7, 8]
Name
= t
= t
2
2
[6]
÷ t
÷ t
[7, 8]
[7, 8]
DD
1
1
s to reach minimum specified voltage (power
Description
V
V
I
I
I
I
REF = 0 MHz
Unloaded outputs, 100 MHz, Select
inputs at V
Unloaded outputs, 66 MHz REF (–1,
–2, –3, –4)
Unloaded outputs, 66 MHz REF (–1,
–2, –3, –4)
30 pF load, All devices
20 pF load, –1H, –5H devices
15 pF load, –1, –2, –3, –4 devices
Measured at 1.4V, F
30 pF load
Measured at 1.4V, F
15 pF load
Measured between 0.8V and 2.0V,
30 pF load
Measured between 0.8V and 2.0V,
15 pF load
Measured between 0.8V and 2.0V,
30 pF load
Measured between 0.8V and 2.0V,
30 pF load
Measured between 0.8V and 2.0V,
15 pF load
OL
OL
OH
OH
IN
IN
= 8 mA (–1, –2, –3, –4)
= 12 mA (–1H, –5H)
= 0V
= V
= –8 mA (–1, –2, –3, –4)
= –12 mA (–1H, –5H)
DD
Test Conditions
Test Conditions
DD
or GND
OUT
OUT
= 66.66 MHz
< 50 MHz
[9]
40.0
45.0
Min
10
10
10
0.05
Min
–40
Min
3.0
2.0
2.4
50.0
50.0
Typ
70(–1H,–5H)
100.0
Max
Max
50.0
25.0
45.0
35.0
20.0
3.6
0.8
0.4
85
30
15
50
7
133.3
133.3
Max
60.0
55.0
2.50
1.50
1.50
2.50
1.50
100
CY2308
Page 6 of 15
MHz
MHz
MHz
Unit
Unit
Unit
mA
mA
mA
mA
ms
μA
μA
μA
pF
pF
pF
ns
ns
ns
ns
ns
°C
%
%
V
V
V
V
V
[+] Feedback