Datasheet

Specifications of LM89CIMM

Temperature Sensor Function
Temp Sensor
Interface Type
Serial (2-Wire)
Output Type
Digital
Package Type
MSOP
Operating Temperature (min)
0C
Operating Temperature (max)
125C
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
3V
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (max)
3.6V
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM89CIMM
Manufacturer:
NS
Quantity:
40
Part Number:
LM89CIMM
Manufacturer:
NS
Quantity:
5 321
Part Number:
LM89CIMM
Quantity:
61
Part Number:
LM89CIMM
Manufacturer:
NS
Quantity:
40
Part Number:
LM89CIMM
Manufacturer:
NSC
Quantity:
61
Part Number:
LM89CIMM
Manufacturer:
NS/国半
Quantity:
20 000
Company:
Part Number:
LM89CIMM
Quantity:
617
Company:
Part Number:
LM89CIMM
Quantity:
617
Part Number:
LM89CIMM/NOPB
Manufacturer:
NS/国半
Quantity:
20 000
Part Number:
LM89CIMMX
Manufacturer:
NS/国半
Quantity:
20 000
www.national.com
2.0 LM89 Registers
2.2 LOCAL and REMOTE TEMPERATURE REGISTERS (LT, RTHB, RTLB)
For LT and RTHB D7–D0: Temperature Data. LSB = 1˚C. Two’s complement format.
For RTLB D7–D5: Temperature Data. LSB = 0.125˚C. Two’s complement format.
The maximum value available from the Local Temperature register is 127; the minimum value available from the Local
Temperature register is -128. The maximum value available from the Remote Temperature register is 127.875; the minimum value
available from the Remote Temperature registers is −128.875.
2.3 STATUS REGISTER (SR)
Power up default is with all bits “0” (zero).
D0: LCRIT: When set to “1” indicates a Local Critical Temperature alarm.
D1: RCRIT: When set to “1” indicates a Remote Diode Critical Temperature alarm.
D2: OPEN: When set to “1” indicates a Remote Diode disconnect.
D3: RLOW: When set to “1” indicates a Remote Diode LOW Temperature alarm
D4: RHIGH: When set to “1” indicates a Remote Diode HIGH Temperature alarm.
D5: LLOW: When set to “1” indicates a Local LOW Temperature alarm.
D6: LHIGH: When set to “1” indicates a Local HIGH Temperature alarm.
D7: Busy: When set to “1” ADC is busy converting.
2.4 CONFIGURATION REGISTER
Power up default is with all bits “0” (zero)
D7: ALERT mask: When set to “1” ALERT interrupts are masked.
(Read Address 03h /Write Address 09h):
ALERT mask
Read Address
<
P7:P0
B0h-BEh
Command Select Address
D7
BFh
FEh
FFh
12h
13h
14h
19h
20h
21h
>
(Read Only Address 02h):
hex
Busy
D7
RUN/STOP
Write Address
<
D6
P7:P0
B0h-BEh
(Read Only Address 00h, 01h):
(Read Only Address 10h):
BFh
12h
13h
14h
19h
20h
21h
NA
NA
LHIGH
Value
Value
BIT
BIT
>
D6
hex
(Continued)
SIGN
D5
0.5
0
D7
D7
LLOW
<
D5
LM89-1 0011 0100
D7:D0
LM89 0011 0001
0000 0000
0000 0000
0000 0000
0101 0101
0000 1010
0000 0000
0000 0001
0110 1110
Power-On-Default State
0.25
D6
D6
64
>
T_CRIT_A
Remote
binary
RHIGH
mask
0.125
D4
D5
D5
D4
32
14
D4
D4
16
0
<
decimal
RLOW
D7:D0
D3
110
85
10
49
52
0
0
0
0
1
D3
0
D3
D3
8
0
>
OPEN
D2
D2
4
0
Register
D2
RTOLB
RHSLB
RLSLB
Name
RDTF
T_CRIT_A
RMID
RDR
RCS
LCS
TH
Local
mask
D2
D1
D1
2
0
RCRIT
Remote Temperature Offset Low
Byte
Remote HIGH Setpoint Low Byte
Remote LOW Setpoint Low Byte
Remote T_CRIT Setpoint
Local T_CRIT Setpoint
T_CRIT Hysteresis
Manufacturers Test Registers
Remote Diode Temperature Filter
Read Manufacturer’s ID
Read Stepping or Die Revision
Code
D1
D0
D0
1
0
Register Function
D1
0
LCRIT
D0
Fault Queue
D0

Related parts for LM89CIMM