M24C16-WDW6T STMicroelectronics, M24C16-WDW6T Datasheet - Page 18

M24C16-WDW6T

Manufacturer Part Number
M24C16-WDW6T
Description
Manufacturer
STMicroelectronics
Datasheet

Specifications of M24C16-WDW6T

Density
16Kb
Interface Type
Serial (I2C)
Organization
2Kx8
Access Time (max)
900ns
Frequency (max)
400KHz
Write Protection
Yes
Data Retention
40Year
Operating Supply Voltage (typ)
3.3/5V
Package Type
TSSOP
Operating Temp Range
-40C to 85C
Supply Current
2mA
Operating Supply Voltage (min)
2.5V
Operating Supply Voltage (max)
5.5V
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
8
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M24C16-WDW6T
Manufacturer:
ST
Quantity:
50 000
Part Number:
M24C16-WDW6T
Manufacturer:
ST
0
Part Number:
M24C16-WDW6T
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
M24C16-WDW6T
Quantity:
1 030
Part Number:
M24C16-WDW6TP
Manufacturer:
ST
Quantity:
32 000
Part Number:
M24C16-WDW6TP
Manufacturer:
ST
Quantity:
1 563
Part Number:
M24C16-WDW6TP
Manufacturer:
ST
Quantity:
8 000
Part Number:
M24C16-WDW6TP
Manufacturer:
ST
Quantity:
150
Part Number:
M24C16-WDW6TP
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
M24C16-WDW6TP
Quantity:
730
Part Number:
M24C16-WDW6TPST
Manufacturer:
ST
0
Device operation
3.7.2
3.7.3
3.7.4
18/40
Current Address Read
For the Current Address Read operation, following a Start condition, the bus master only
sends a device select code with the Read/Write bit (RW) set to 1. The device acknowledges
this, and outputs the byte addressed by the internal address counter. The counter is then
incremented. The bus master terminates the transfer with a Stop condition, as shown in
Figure
Sequential Read
This operation can be used after a Current Address Read or a Random Address Read. The
bus master does acknowledge the data byte output, and sends additional clock pulses so
that the device continues to output the next byte in sequence. To terminate the stream of
bytes, the bus master must not acknowledge the last byte, and must generate a Stop
condition, as shown in
The output data comes from consecutive addresses, with the internal address counter
automatically incremented after each byte output. After the last memory address, the
address counter ‘rolls-over’, and the device continues to output data from memory address
00h.
Acknowledge in Read mode
For all Read commands, the device waits, after each byte read, for an acknowledgment
during the 9
time, the device terminates the data transfer and switches to its Standby mode.
10, without acknowledging the byte.
th
bit time. If the bus master does not drive Serial Data (SDA) Low during this
Figure
10.
Doc ID 5067 Rev 13
M24C16, M24C08, M24C04, M24C02, M24C01