G5V1DC24 Omron, G5V1DC24 Datasheet - Page 3

G5V1DC24

Manufacturer Part Number
G5V1DC24
Description
Manufacturer
Omron
Type
Signal Relayr
Datasheet

Specifications of G5V1DC24

Relay Construction
Non-Latching
Contact Arrangement
SPDT
Coil Voltage Dc
24V
Coil Current
6.25mA
Contact Form
1 Form C
Voltage Rating (vdc)
60V
Voltage Rating (vac)
125V
Dropout Volt (min)
2.4VDCV
Coil Resistance
3.84kohm
Pick-up Voltage (max)
19.2VDC
Maximum Power Rating
30W/62.5VA
Operate Time
5ms
Contact Current Rating
1A
Contact Material
Ag/Au Clad
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Sealed
Product Height (mm)
10mm
Product Depth (mm)
7.5mm
Product Length (mm)
12.5mm
Operating Temp Range
-40C to 70C
Pin Count
6
Mounting Style
Through Hole
Termination Style
PC Pin
Package / Case
DIP
Lead Free Status / Rohs Status
Compliant
■ Characteristic Data
Dimensions
Note: 1. All units are in millimeters unless otherwise indicated. To convert millimeters into inches, multiply by 0.03937.
G5V-1
Precautions
Long-term Continuously ON Contacts
Using the Relay in a circuit where the Relay will be ON continuously
for long periods (without switching) can lead to unstable contacts,
because the heat generated by the coil itself will affect the insulation,
causing a film to develop on the contact surfaces. Be sure to use a
fail-safe circuit design that provides protection against contact failure
or coil burnout.
Maximum Switching Capacity
2. Numbers in parentheses are reference values.
3. Tolerance: ±0.1
4. Orientation marks are indicated as follows:
DC resistive load
Rated Operating voltage (V)
10 max.
(9.9)
3.5
AC
resistive
load
0.5
0.5
0.3
12.5 max.
(12.3)*
Electrical Service Life
5,000
3,000
1,000
700
500
300
100
0.3
70
50
125-VAC
resistive
load
Rated Operating current (A)
7.5 max.
(7.3)*
0.5
* Average value
24-VDC resistive load
Terminal Arrangement/
Internal Connections
(Bottom View)
Relay Handling
When washing the product after soldering the Relay to a PCB, use a
water-based solvent or alcohol-based solvent, and keep the solvent
temperature to less than 40°C. Do not put the Relay in a cold clean-
ing bath immediately after soldering.
1
10
2
9
Note: The maximum coil voltage refers to the maxi-
Low Signal Relay
5
6
Ambient Temperature vs.
Maximum Coil Voltage
Six, 1-dia. holes
mum value in a varying range of operating
power voltage, not a continuous voltage.
(1.07)
Ambient temperature (°C)
Mounting Holes
(Bottom View)
Rated coil voltage
2.54 7.62
10.16+0.1
G5V-1
5.08+0.1
(1.07)
(1.11)
(1.11)
47