Specifications of HE9Z-D5Y

Actuator / Cap Color
Yellow
For Use With
HE5B Series Pushbutton Enabling Switches
Enabling Switches
HE5B Key features include:
Specifi cations
Conforming to Standards
Application Standards
Operating Temperature
Relative Humidity
Storage Temperature
Operating Environment
Contact Resistance
Insulation Resistance (DC megger)
Impulse Withstand Voltage
Operating Frequency
Mechanical Life
Electrical Life
Shock Resistance
Vibration Resistance
Terminal Style
Recommended Wire
Solder Heat Resistance
Terminal Pulling Strength
Recommended Tightening Torque of Locking Ring
Degree of Protection
Conditional Short-circuit Current
Operator Strength
Weight (approx.)
Ergonomically-designed OFF-ON-OFF 3-position operation
Easy recognition of position 1 ‡ 2 transition, made possible by snap action switch
Suffi cient load difference is provided for shifting from position 2 ‡ 3
Light force needed to maintain position 2, so that operators can easily use the enabling
switch
The switch does not turn ON when being released from position 3 (OFF when pressed)
to position 1 (OFF when released) (IEC60204-1, 9.2.5.8)
Two contacts are provided for safety
IP65 (using the waterproof rubber cover)
Mounts in a 16mm (5/8”) round hole
HE5B Series Pushbutton Enabling Switch
USA: 800-262-IDEC
IEC60947-5-1, EN60947-5-1 (DEMKO approval), JIS C8201-5-1, UL508
(UL recognized), CSA C22.2, No. 14 (c-UL recognized)
ISO 12100/EN292, IEC60204-1/EN60204-1
ISO11161/prEN11161, ISO10218/EN775
ANSI/RIA R15.06, ANSI B11.19
Silicone rubber boot: –25 to 60°C (no freezing)
NBR/PVC Polyblend rubber boot: –10 to 60°C (no freezing)
45 to 85% RH (no condensation)
–40 to +80°C (no freezing)
Degree of pollution: 2 (panel inside/terminal side)
Degree of pollution: 3 (panel outside/operator side)
50 mΩ maximum (initial value)
Between live and dead metal parts: 100 MΩ minimum
Between terminals of different pole: 100 MΩ minimum
1.5 kV
1200 operations per hour
Position 1‡ 2‡ 1: 1,000,000 operations minimum
Position 1‡ 2‡ 3‡ 1: 100,000 operations minimum
100,000 operations minimum
Operating extremes: 100 m/s
Damage limits: 500 m/s
Operating extremes: 5 to 55 Hz, amplitude 0.5 mm minimum
Damage limits: 5 to 55 Hz, amplitude 0.5 mm minimum
Solder Terminal
0.5 mm
260°C, 3 seconds maximum
20 N minimum
0.29 to 0.49 N·m
IP65
50A (250V) (Use 250V/10A fast acting type fuse for short circuit protection.)
250N minimum (when pressing the entire surface of the operator)
9 g
2
maximum per line (20AWG)
2
(50 G)
2
(10 G)
Canada: 888-317-IDEC
HE5B Series
413

Related parts for HE9Z-D5Y

HE9Z-D5Y Summary of contents

Page 1

... N minimum 0.29 to 0.49 N·m IP65 50A (250V) (Use 250V/10A fast acting type fuse for short circuit protection.) 250N minimum (when pressing the entire surface of the operator USA: 800-262-IDEC Canada: 888-317-IDEC HE5B Series 413 ...

Page 2

... Mounting Hole Layout www.idec.com Enabling Switches 1. Recommended tightening torque for Locking Ring: 0.29 to 0.49 N·mm. 2. Use a lock nut tool to screw on the lock nut (see page 415). Anti-rotation ring Lock nut ...

Page 3

... Approx NO1-C1 NO2-C2 NO1-C1 NO2-C2 Panel Thickness 0 Locking Ring Anti-rotation Ring Rubber Boot Solder Terminal Width 2.8 × 0. Material HE9Z-D5Y HE9Z-D5B HE9Z-D5N1 NBR/PVC cover comes in gray only. USA: 800-262-IDEC Canada: 888-317-IDEC HE5B Series Position 2 Position 3 ±0.3 ±0.3 ±0.5 ±0.5 2.3 3.0 3 ...

Page 4

... HE1B/HE2B/HE3B • When installing the enabling switch ensure that it cannot be accidently activated. For example, a protrusion from a teaching pendant could cause the enabling switch to be activated by the weight of the teaching pendant. USA: 800-262-IDEC Canada: 888-317-IDEC General Information Positioning Projection (M4 screw x 3) base ...

Related keywords