M85049/41-10A Amphenol, M85049/41-10A Datasheet - Page 82

no-image

M85049/41-10A

Manufacturer Part Number
M85049/41-10A
Description
80P7336
Manufacturer
Amphenol
Datasheet

Specifications of M85049/41-10A

Connector Shell Size
18
GT Connectors
solder contacts
Machined copper alloy contacts in a full range of sizes, with closed entry socket design in the
size 12 and 16 contacts. A heavy silver-plated finish is deposited on all MS style solder con-
tacts for maximum corrosion resistance, maximum current carrying capacity and low millivolt
drop. Gold plated contacts are also available. (See how to order, pg. 83).
* Solder Wells Filled
** Contact ratings as stated are test ratings only. The connector may not withstand full rated current through
* The values listed in Table I represent operating val-
Service
Rating
10-40569
10-597107-16( ) or
10-40568
10-40599
10-597107-17( ) or
10-40598
10-33646
10-597107-13( ) or
10-33644
10-35531
10-35532
10-35529
10-35530
10-35527
10-35528
Inst.
A
D
E
B
C
MS
all contacts continuously. Please note that the electrical data given is not an establishment of electrical
safety factors. This is left entirely in the designer’s hands as he can best determine which peak voltage,
switching surges, transients, etc. can be expected in a particular circuit.
ues which include a generous safety factor. It may
be necessary for some applications to exceed the
operating voltages listed here. If this is necessary,
designers will find Table II useful for determining the
degree to which the recommended values of Table I
can be exceeded.
CONTACT ARRANGEMENT
Number
Operating Voltage*
1250
1750
2450
4200
Part
Recommended
250
700
DC
at Sea Level
SERVICE RATING
AC (RMS)
1250
1750
3000
Table I
200
500
900
Creepage
Effective
Distance
1/16
1/8
3/16
1/4
5/16
1
Nom.
Socket
Socket
Socket
Socket
Socket
Socket
Socket
Pin/
Pin
Pin
Pin
Pin
Pin
Pin
Mechanical
Spacing
1/16
1/8
3/16
1/4
5/16
Nom.
Mating End
† Not corrected for changes in density due to variations in temperature
** No attempt has been made to recommend operating voltages. The designer must determine his own oper-
Service
Rating
16 Short
Inst.
A
D
E
B
C
16 Long
SOLDER CONTACTS*
MS
ating voltage by the application of a safety factor to the above derating chart to compensate for circuit tran-
sients, surges, etc.
Size
12
8
4
0
Airspace
1/32
1/16
1/8
3/16
1/4
5/16
Distance
Nominal
80
Creepage
1/16
1/8
3/16
1/4
5/16
1
Wire Barrel
Size
16
16
12
8
4
0
Flashover
AC (RMS)
Minimum
Voltage
1400
2800
3600
4500
5700
8500
Level Conditions
DERATING** CHART
ALTITUDE VOLTAGE
Standard Sea
AC (RMS)
Voltage
1000
2000
2800
3500
4500
7000
Table II
Test
Allowable
Wire Size
16
18
20
22
16
18
20
22
12
14
10
Flashover
AC (RMS)
8
4
6
0
1
2
Minimum
Voltage
Pressure Altitude †
1000
1100
1300
550
800
900
50,000 Feet
AC (RMS)
Voltage
Test
400
600
675
750
825
975
Test Current**
Amps
Flashover
AC (RMS)
Minimum
150
125
100
Voltage
13
10
13
10
23
17
46
33
80
60
Pressure Altitude †
5
5
7.5
7.5
325
450
500
550
600
700
70,000 Feet
AC (RMS)
Voltage
Test
260
360
400
440
480
560