5962-8513102XA Intersil, 5962-8513102XA Datasheet

no-image

5962-8513102XA

Manufacturer Part Number
5962-8513102XA
Description
Analog Multiplexer Dual 8:1 28-Pin CDIP
Manufacturer
Intersil
Type
Analog Multiplexerr
Datasheet

Specifications of 5962-8513102XA

Package
28CDIP
Maximum On Resistance
300@±15V Ohm
Maximum Propagation Delay Bus To Bus
500@±15V ns
Maximum High Level Output Current
20 mA
Multiplexer Architecture
8:1
Power Supply Type
Single|Dual

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
5962-8513102XA
Manufacturer:
INTERS
Quantity:
142
PMIC N/A
DSCC FORM 2233
REV
SHEET
REV
SHEET
REV STATUS
OF SHEETS
THIS DRAWING IS AVAILABLE
DEPARTMENT OF DEFENSE
APR 97
AND AGENCIES OF THE
LTR
MICROCIRCUIT
C
D
A
B
E
F
FOR USE BY ALL
STANDARD
DEPARTMENTS
DRAWING
AMSC N/A
Add case outlines, terminal connections and thermal resistance values for case
outlines 2 and 3. For device type 01, 02, and 03, add subgroup 3 to I
test, add R
conditions for t
and t
V
Add device types 07, 08, and 09. Table I changes. Editorial changes
throughout.
Changes in accordance with NOR 5962-R061-95.
Changes in accordance with NOR 5962-R032-96.
Incorporate NOR’s and current requirements.
Editorial changes throughout. - drw
Make change to the t
and 03 as specified under Table I. - ro
35
15
F
F
S
for R
OFF(EN)
36
16
F
F
DS2
DS1
test, add test condition circuits. Editorial changes throughout.
tests, change value of I
37
17
ON(A)
F
F
test, add V
PREPARED BY
CHECKED BY
APPROVED BY
DRAWING APPROVAL DATE
REVISION LEVEL
and t
18
ON(A)
REV
SHEET
F
RAY MONNIN
D. A. DiCENZO
MARCIA B. KELLEHER
OFF(A)
ISO
and t
19
F
test, delete V
DESCRIPTION
OFF(A)
tests, change C
20
86-06-30
F
D
for R
F
subgroup 9 test limit for devices 01, 02,
21
F
F
1
CT
DS1
test, change R
test, change value of I
22
L
F
F
2
test condition for t
REVISIONS
23
F
F
3
L
MICROCIRCUIT, LINEAR, CMOS, MULTIPLEXER /
DEMULTIPLEXER, MONOLITHIC SILICON
SHEET
24
and C
F
F
4
SIZE
A
ON(EN)
L
IH
25
F
F
5
D
test
DEFENSE SUPPLY CENTER COLUMBUS
and I
and
26
IL
F
F
6
COLUMBUS, OHIO 43218-3990
CAGE CODE
67268
http://www.dscc.dla.mil
27
F
F
7
DATE (YR-MO-DA)
1 OF
28
88-08-26
93-06-28
95-01-25
96-01-09
02-12-30
07-09-13
F
F
8
37
29
F
F
9
30
10
F
F
5962-85131
31
11
F
F
5962-E563-07
D. A. DiCENZO
APPROVED
M. A. FRYE
M. A. FRYE
M. A. FRYE
R. MONNIN
R. HEBER
32
12
F
F
33
13
F
F
34
14
F
F

Related parts for 5962-8513102XA

5962-8513102XA Summary of contents

Page 1

... Editorial changes throughout. S DS2 Add device types 07, 08, and 09. Table I changes. Editorial changes B throughout. C Changes in accordance with NOR 5962-R061-95. D Changes in accordance with NOR 5962-R032-96. Incorporate NOR’s and current requirements. E Editorial changes throughout. - drw Make change to the t ...

Page 2

... Differential 4-channel MUX/DEMUX with overvoltage protection HI506 Single 16-channel MUX/DEMUX HI507 Differential 8-channel MUX/DEMUX HI509 Differential 4-channel MUX/DEMUX Terminals 16 28 CQCC1-N20 20 CQCC1-N28 28 SIZE A A Lead finish (see 1.2.3) Circuit function Package style Dual-in-line Dual-in-line Square leadless chip carrier Square leadless chip carrier REVISION LEVEL SHEET F 5962-85131 2 ...

Page 3

... Device types 01-03 .................................................................................. 4.0 V Device types 04-09 .................................................................................. 2.4 V Ambient operating temperature range (T STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR ................................................. -55°C to +125°C A SIZE whichever comes first = +75° +75° +75° +75°C A 5962-85131 REVISION LEVEL SHEET F 3 ...

Page 4

... Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical tests for each subgroup are described in table I. STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 http://assist.daps.dla.mil/quicksearch/ SIZE A REVISION LEVEL F or http://assist.daps.dla.mil or 5962-85131 SHEET 4 ...

Page 5

... All -50 +50 01, 02, 1 03, 07, -10 +10 08, 09 04, 05 All -50 +50 01, 02, 1 03, 07, -10 +10 08 01, 04 -300 +300 07 02, 08 -200 +200 03, 06, -100 +100 09 05 -150 +150 5962-85131 REVISION LEVEL SHEET F Unit µ ...

Page 6

... REVISION LEVEL SHEET F Unit ...

Page 7

... Min Max 01, 02 -2.0 +2.0 03, 04, 05 -2.0 +2 01, 02 -2.0 +2.0 03, 04, 05 -2.0 +2 01, 02 2.0 03 04, 05 2.0 07, 08 3.0 09 2.4 06 2.0 01, 02 -1.0 03 04, 05, 07, 08, -1 -1.0 01, 02 03, 04, 2.0 05, 06 07, 08 3 All -1.0 5962-85131 REVISION LEVEL SHEET F Unit µ ...

Page 8

... Group A Device Limits type Min Max 01, 02 1.8 04, 05 2.0 07, 08, 1 300 400 01, 02 1.8 04, 05 2.0 07, 08, 1 300 400 04 2.4 04 2.4 01. 02 01, 02 04 5962-85131 REVISION LEVEL SHEET F Unit kΩ Ω kΩ Ω kΩ ...

Page 9

... +25°C, see figure kΩ pF +25°C, see figure 3 A SIZE A Device Limits type Min Max 02 03 04, 05 01, 02 04, 05 07, 08 All 10 01, 02, 7 03, 07, -50 08, 09 04, 05, 7 -50 06 04, 05, 7 -50 06 01, 02 03, 04, 05 07, 08 5962-85131 REVISION LEVEL SHEET F Unit ...

Page 10

... In addition, the manufacturer's PIN may also be marked. For packages where marking of the entire SMD PIN number is not feasible due to space limitations, the manufacturer has the option of not marking the "5962-" on the device. 3.5.1 Certification/compliance mark. A compliance indicator “C” shall be marked on all non-JAN devices built in compliance to MIL-PRF-38535, appendix A. The compliance indicator “ ...

Page 11

... OUT B NC OUT Enable OUT GND GND GND OUT REF Enable Enable Enable GND --- --- --- --- --- --- --- OUT A OUT OUT A --- FIGURE 1. Terminal connections. SIZE OUT GND GND GND REF REF Enable Enable Enable OUT OUT A OUT REVISION LEVEL SHEET OUT GND Enable OUT A 5962-85131 11 ...

Page 12

... DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 CHANNEL SELECTED NONE CHANNEL SELECTED NONE 1A, 1B 2A, 2B 3A, 3B 4A, 4B FIGURE 2. Truth tables. SIZE A Device types 02, 05, and 08 CHANNEL SELECTED NONE 8A, 8B 5962-85131 REVISION LEVEL SHEET F 12 ...

Page 13

... FIGURE 3. Break-before-make test circuit and waveforms. STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 SIZE A REVISION LEVEL F 5962-85131 SHEET 13 ...

Page 14

... FIGURE 3. Break-before-make test circuit and waveforms – continued. STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 SIZE A REVISION LEVEL F 5962-85131 SHEET 14 ...

Page 15

... FIGURE 3. Break-before-make test circuit and waveforms – continued. STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 SIZE A REVISION LEVEL F 5962-85131 SHEET 15 ...

Page 16

... FIGURE 3. Break-before-make test circuit and waveforms – continued. STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 SIZE A REVISION LEVEL F 5962-85131 SHEET 16 ...

Page 17

... FIGURE 3. Break-before-make test circuit and waveforms – continued. STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 SIZE A REVISION LEVEL F 5962-85131 SHEET 17 ...

Page 18

... FIGURE 3. Break-before-make test circuit and waveforms – continued. STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 SIZE A REVISION LEVEL F 5962-85131 SHEET 18 ...

Page 19

... FIGURE 3. Break-before-make test circuit and waveforms – continued. STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 SIZE A REVISION LEVEL F 5962-85131 SHEET 19 ...

Page 20

... STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 FIGURE 4. Switching times test circuits. SIZE A 5962-85131 REVISION LEVEL SHEET F 20 ...

Page 21

... STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 FIGURE 4. Switching times test circuits – continued. SIZE A 5962-85131 REVISION LEVEL SHEET F 21 ...

Page 22

... STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 FIGURE 4. Switching times test circuits – continued. SIZE A 5962-85131 REVISION LEVEL SHEET F 22 ...

Page 23

... STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 FIGURE 4. Switching times test circuits – continued. SIZE A 5962-85131 REVISION LEVEL SHEET F 23 ...

Page 24

... STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 FIGURE 4. Switching times test circuits – continued. SIZE A 5962-85131 REVISION LEVEL SHEET F 24 ...

Page 25

... STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 FIGURE 4. Switching times test circuits – continued. SIZE A 5962-85131 REVISION LEVEL SHEET F 25 ...

Page 26

... STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 FIGURE 4. Switching times test circuits – continued. SIZE A 5962-85131 REVISION LEVEL SHEET F 26 ...

Page 27

... OUT A + OUT 100 GND (ENABLE TO I/O) FIGURE 4. Switching times test circuits – continued. SIZE A I/O -15 V 100 GND . -10 V +10 V +10 V -10 V GND +5 V PULSE GEN I/O -15 V 100 +10 V -10 V GND PULSE GEN +5 V 5962-85131 REVISION LEVEL SHEET F 27 ...

Page 28

... STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 FIGURE 4. Switching times test circuits – continued. SIZE A 5962-85131 REVISION LEVEL SHEET F 28 ...

Page 29

... STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 FIGURE 4. Switching times test circuits – continued. SIZE A 5962-85131 REVISION LEVEL SHEET F 29 ...

Page 30

... STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 FIGURE 4. Switching times test circuits – continued. SIZE A 5962-85131 REVISION LEVEL SHEET F 30 ...

Page 31

... STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 FIGURE 4. Switching times test circuits – continued. SIZE A 5962-85131 REVISION LEVEL SHEET F 31 ...

Page 32

... STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 FIGURE 4. Switching times test circuits – continued. SIZE A 5962-85131 REVISION LEVEL SHEET F 32 ...

Page 33

... STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 FIGURE 4. Switching times test circuits – continued. SIZE A 5962-85131 REVISION LEVEL SHEET F 33 ...

Page 34

... STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 FIGURE 4. Switching times test circuits – continued. SIZE A 5962-85131 REVISION LEVEL SHEET F 34 ...

Page 35

... STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 FIGURE 4. Switching times test circuits – continued. SIZE A 5962-85131 REVISION LEVEL SHEET F 35 ...

Page 36

... MIL-STD-883. ( +125°C, minimum. A (3) Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883. STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 SIZE A REVISION LEVEL F 5962-85131 SHEET 36 ...

Page 37

... SMD. DSCC will maintain a record of users and this list will be used for coordination and distribution of changes to the drawings. Users of drawings covering microelectronics devices (FSC 5962) should contact DSCC-VA, telephone (614) 692-0544. 6.5 Comments. Comments on this drawing should be directed to DSCC-VA, Columbus, Ohio 43218-3990, or telephone (614) 692-0547 ...

Page 38

... DSCC-VA. This information bulletin is superseded by the next dated revision of MIL-HDBK-103 and QML-38535. DSCC maintains an online database of all current sources of supply at http://www.dscc.dla.mil/Programs/Smcr/. Standard microcircuit drawing PIN 1/ 5962-85131013A 5962-8513101XA 5962-85131023A 5962-8513102XA 5962-85131032A 5962-8513103EA 5962-8513104XA 5962-8513105XA 5962-85131062C 5962-8513106EA 5962-85131073A 5962-85131073C ...

Page 39

... The information contained herein is disseminated for convenience only and the Government assumes no liability whatsoever for any inaccuracies in the information bulletin. Vendor name and address Intersil Corporation 1001 Murphy Ranch Road Milpitas, CA 95035-6803 Point of contact: 1650 Robert J. Conlan Blvd. Palm Bay, FL 32905 ...

Related keywords