SI3215-C-FM Silicon Laboratories Inc, SI3215-C-FM Datasheet - Page 106
SI3215-C-FM
Manufacturer Part Number
SI3215-C-FM
Description
IC SLIC/CODEC 1CH 38QFN
Manufacturer
Silicon Laboratories Inc
Series
ProSLIC®r
Datasheet
1.SI3215-B-FM.pdf
(118 pages)
Specifications of SI3215-C-FM
Package / Case
*
Function
Subscriber Line Interface Concept (SLIC), CODEC
Interface
PCM, SPI
Number Of Circuits
1
Voltage - Supply
3.13 V ~ 5.25 V
Current - Supply
88mA
Power (watts)
700mW
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Includes
Audio Tone Generation, BORSCHT Functions, FSK Generation, Voice Loopback Test Modes
Product
SLIC
Supply Voltage (min)
3.13 V
Supply Current
88 mA
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Number Of Channels
1
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
SI3215-C-FM
Manufacturer:
SiliconL
Quantity:
230
Company:
Part Number:
SI3215-C-FMR
Manufacturer:
HOLTEK
Quantity:
26 000
Si3215
106
Addr
69
70
71
72
73
74
FSK Amplitude Coefficient for Space.
When FSKEN = 1 and REL = 1, this register sets the amplitude to be used when gener-
ating a space or “0”. When the active timer (OAT1) expires, the value of this register is
loaded into oscillator 1 instead of OSC1X.
FSK Frequency Coefficient for Space.
When FSKEN = 1 and REL = 1, this register sets the frequency to be used when gener-
ating a space or “0”. When the active timer (OAT1) expires, the value of this register is
loaded into oscillator 1 instead of OSC1.
FSK Amplitude Coefficient for Mark.
When FSKEN = 1 and REL = 1, this register sets the amplitude to be used when gener-
ating a mark or “1”. When the active timer (OAT1) expires, the value of this register is
loaded into oscillator 1 instead of OSC1X.
FSK Frequency Coefficient for Mark.
When FSKEN = 1 and REL = 1, this register sets the frequency to be used when gener-
ating a mark or “1”. When the active timer (OAT1) expires, the value of this register is
loaded into oscillator 1 instead of OSC1.
FSK Transition Parameter from 0 to 1.
When FSKEN = 1 and REL = 1, this register defines a gain correction factor that is
applied to signal amplitude when transitioning from a space (0) to a mark (1).
FSK Transition Parameter from 1 to 0.
When FSKEN = 1 and REL = 1, this register defines a gain correction factor that is
applied to signal amplitude when transitioning from a mark (1) to a space (0).
Table 42. FSK Control Indirect Registers Description
Description
Rev. 0.92
Reference Page
35 and AN32
35 and AN32
35 and AN32
35 and AN32
35 and AN32
35 and AN32