1586018-8 TE Connectivity, 1586018-8 Datasheet - Page 5

Pin & Socket Connectors 8P PM PLG VALULOK V0

1586018-8

Manufacturer Part Number
1586018-8
Description
Pin & Socket Connectors 8P PM PLG VALULOK V0
Manufacturer
TE Connectivity
Datasheets

Specifications of 1586018-8

Product Type
Connector
Connector Type
Housing
Termination Method To Wire/cable
Crimp
Sealed
No
Ul File Number
E28476
Csa File Number
208567
Mating Retention Type
Latching
Contact Current Rating, Max (a)
9
Operating Voltage Reference
AC
Operating Voltage (vac)
600
Profile Height (y-axis) (mm [in])
9.80 [0.386]
Number Of Positions
8
Number Of Rows
2
Centerline (mm [in])
4.20 [0.165]
Mating Retention
With
Selectively Loaded
No
Length (x-axis) (mm [in])
18.00 [0.7087]
Width (z-axis) (mm [in])
20.00 [0.787]
Contact Type
Pin
Contact Design
Formed Pin
Connector Style
Plug
Mating Alignment
With
Mating Alignment Type
Keyed
Housing Color
Natural
Ul Flammability Rating
UL 94V-0
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Agency/standard
UL, CSA
Ul Rating
Recognized
Circuit Identification Feature
With
Operating Temperature (°c [°f])
-40 – +105 [-40 – +221]
Applies To
Wire/Cable
Application Use
Wire-to-Panel, Wire-to-Wire, Wire-to-Wire / Wire-to-Panel
Contact Transmits (typical Application)
Signal (Data)
Pick And Place Cover
Without
Packaging Method
Bag
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
1586018-8
Manufacturer:
TE Connectivity AMP Connectors
Quantity:
6 043
4.
4.1.
4.2.
4.3.
4.4.
Rev B
QUALITY ASSURANCE PROVISIONS
Qualification Testing
A.
B.
Requalification Testing
If changes significantly affecting form , fit or function are m ade to the product or m anufacturing process,
product assurance shall coordinate requalification testing, consisting of all or part of the original testing
sequence as determ ined by developm ent/product, quality and reliability engineering.
Acceptance
Acceptance is based on verification that the product m eets the requirem ents of Figure 1. Failures
attributed to equipm ent, test setup or operator deficiencies shall not disqualify the product. If product
failure occurs, corrective action shall be taken and specim ens resubm itted for qualification. Testing to
confirm corrective action is required before resubm ittal.
Quality Conform ance Inspection
The applicable quality inspection plan shall specify the sam pling acceptable quality level to be used.
Dim ensional and functional requirem ents shall be in accordance with the applicable product drawing
and this specification.
Specim en Selection
Specim ens shall be prepared in accordance with applicable Instruction Sheets and shall be
selected at random from current production. Each test group shall consist of a m inim um of 5
specim ens.
Test Sequence
Qualification inspection shall be verified by testing specim ens as specified in Figure 2.