5962-9204102MEA Maxim Integrated Products, 5962-9204102MEA Datasheet - Page 4

no-image

5962-9204102MEA

Manufacturer Part Number
5962-9204102MEA
Description
Analog Switch Quad SPST 16-Pin CDIP
Manufacturer
Maxim Integrated Products
Type
Analog Switchr
Datasheet

Specifications of 5962-9204102MEA

Package
16CDIP
Maximum On Resistance
160@10.8V Ohm
Maximum High Level Output Current
30 mA
Maximum Turn-off Time
200@12V ns
Maximum Turn-on Time
400@12V ns
Switch Architecture
SPST
Power Supply Type
Single|Dual

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
5962-9204102MEA
Manufacturer:
VISHAY
Quantity:
1 001
ORDERING INFORMATION:
DG441AK/883B
DG441AZ/883B
Figure 2. Switching Time: See Commercial Data Sheet.
Figure 3. Charge Injection: See Commercial Data Sheet.
QUALITY ASSURANCE
Sampling and inspection procedures shall be in accordance with MIL-Prf-38535, Appendix A as specified in Mil-
Std-883.
Screening shall be in accordance with Method 5004 of Mil-Std-883. Burn-in test Method 1015:
Quality conformance inspection shall be in accordance with Method 5005 of Mil-Std-883, including Groups A, B,
C, and D inspection.
Group A inspection:
Group C and D inspections:
a. End-point electrical parameters shall be specified in Table 1.
b. Steady-state life test, Method 1005 of Mil-Std-883:
TABLE 2.
----------------------------
1. Test Condition, A, B, C, or D.
2. TA = +125 C minimum.
3. Interim and final electrical test requirements shall be specified in Table 2.
1. Tests as specified in Table 2.
2. Selected subgroups in Table 1, Method 5005 of Mil-Std-883 shall be omitted.
1. Test condition A, B, C, D.
2. TA = +125 C, minimum.
3. Test duration, 1000 hours, except as permitted by Method 1005 of Mil-Std-883.
Group C and D End-Point Electrical Parameters
*
PDA applies to Subgroup 1 only.
Mil-Std-883 Test Requirements
Group A Test Requirements
Interim Electric Parameters
Final Electrical Parameters
20 LCC
16 CDIP
Method 5004
Method 5005
Method 5005
Method 5005
Electrical Characteristics of DG441A/DG442A/883B
ELECTRICAL TEST REQUIREMENTS
DG442AK/883B
DG442AZ/883B
per Method 5005, Table 1
16 CDIP
20 LCC
Subgroups
1*, 2, 3, 9
1, 2, 3, 9
1
1
19-0093
Page 5 of
Rev. C
6