XPSAC5121P Crouzet USA, XPSAC5121P Datasheet - Page 38
XPSAC5121P
Manufacturer Part Number
XPSAC5121P
Description
89H6659
Manufacturer
Crouzet USA
Datasheet
1.XPSMCCPC.pdf
(274 pages)
Specifications of XPSAC5121P
Contact Current Max
40mA
Contact Voltage Ac Nom
24V
Contact Voltage Dc Nom
24V
Contact Configuration
3PST-NO
Relay Mounting
DIN Rail
External Height
66mm
External Width
114mm
External Depth
22.5mm
Rohs Compliant
No
- Current page: 38 of 274
- Download datasheet (15Mb)
Presentation
XPSMFCIO2401
XPSMFAO801
XPSMFDO801
XPSMFDIO241601
Safety automation system solutions
Preventa™ safety PLCs
Modular, XPSMF60
Rack, power supply and CPU
In addition to the inputs/outputs available as standard on the optional “in rack” cards,
the modular safety PLC XPSMF60 can be connected to safety remote input modules
XPSMF1 and/or safety remote output modules XPSMF2 and/or safety remote mixed
I/O modules XPSMF3.
The safety remote input, output and mixed I/O modules can be located within the
vicinity of the machines to be monitored, thus reducing cabling.
Communication between these safety modules and the safety PLC XPSMF60 is
performed on an Ethernet network using the SafeEthernet safety protocol, via the
integrated RJ45 switched Ethernet communications ports.
(1) Removable screw terminal blocks are provided with the power supply and “in rack” I/O cards.
(2) Use shielded dual twisted pair cables, maximum length 984 ft (300 m), short-circuit unused
analog inputs.
XPSMFCIO2401 2
XPSMFDIO241601 24
XPSMFAO801
XPSMFDO801
Safety inputs and outputs
Mixed I/O cards
Card
Card
Analog output card
Card
Relay output card
Card
Remote inputs and outputs
Counting inputs
N°
(1)
Digital inputs
N°
Analog outputs
N°
8
Relay outputs
N°
8
(1) (2)
c 5 V
Incremental
encoders
Independent and configurable
counting inputs (one channel for
counting and one channel for
increasing or decreasing
counting direction)
(1) (2)
Type
Safety detection
Limit switches,
Guard switches, with reset and
with actuator,
Light curtains type 2 and type 4,
Safety mats and sensing
edges…
Safety dialog
Mushroom head Emergency
stops,
Enclosures for control and
signalling units,
Two-hand control stations…
Functions
Closed circuit scanning of output channels,
Single-pole measuring of 0 to 10 V voltages,
Measuring, using jumper, 0/4 to 20 mA currents (with 500 W external
resistor)
Type
Safety actuators
Contactors-motors,
Control relays,
Variable speed drives.
Safety dialog
Beacons and indicator banks,
Rotating mirror beacons, Sirens…
(continued)
c 24 V
Sensors
2/3-wire
PNP/NPN
Digital outputs
N°
4
Digital outputs
N°
16
Type
Safety actuators
Contactors-motors,
Control relays,
Variable speed drives.
Safety dialog
Beacons and indicator banks,
Rotating mirror beacons,
Sirens…
Type
Safety actuators
Contactors-motors,
Control relays,
Variable speed drives.
Safety dialog
Beacons and indicator
banks,
Rotating mirror beacons,
Sirens…
2/37
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
Related parts for XPSAC5121P
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
SCREW SOCKET (OT08PC)
Manufacturer:
Crouzet USA
Datasheet:
Part Number:
Description:
PANEL PLATE FOR 813
Manufacturer:
Crouzet USA
Datasheet:
Part Number:
Description:
Controller; CTD46 Dual Display Temperature, 1/16 DIN, NEMA 4X, 110/220VAC
Manufacturer:
Crouzet USA
Datasheet:
Part Number:
Description:
11R1084
Manufacturer:
Crouzet USA
Datasheet:
Part Number:
Description:
11R1086
Manufacturer:
Crouzet USA
Datasheet:
Part Number:
Description:
11R1087
Manufacturer:
Crouzet USA
Datasheet:
Part Number:
Description:
11R1089
Manufacturer:
Crouzet USA
Datasheet:
Part Number:
Description:
11R1078
Manufacturer:
Crouzet USA
Datasheet:
Part Number:
Description:
11R1079
Manufacturer:
Crouzet USA
Datasheet: