Specifications of XPSBF1132P
Contact Current Max
8mA
Contact Voltage Dc Nom
24V
Contact Configuration
DPST-NO
Relay Mounting
DIN Rail
External Height
66mm
External Width
114mm
External Depth
22.5mm
Rohs Compliant
Yes
- Current page: 113 of 274
- Download datasheet (15Mb)
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
Wiring diagrams
Configuration 5 (locking of guard with start test, automatic or unmonitored start) = function 1.
Configuration 6 (locking of guard with start test, monitored start) = function 2.
(1) Automatic start.
(2) Function 1 safety outputs.
Configuration 5
Automatic start
Key
Input 1 C1-I1, (C4-I4)
Input 2 C2-I2, (C5-I5)
Automatic start C3-I3,
(C6-I6)
N.O. output 13-14/23-24/
33-34, (43-44/53-54/63-64)
Signalling output Y84,
(Y94)
Configuration 6
Monitored start
Key
Input 1 C1-I1, (C4-I4)
Input 2 C2-I2, (C5-I5)
Start button C3-I3,
(C6-I6)
N.O. output 13-14/23-24/
33-34, (43-44/53-54/63-64)
Signalling output Y84,
(Y94)
Presentation:
page 2/106
2/112
XPSMP
Guard monitoring with start test and synchronization time = 1.5 ms
Functional diagrams
+
0 V
24 V
F1
0
0
A2
A1
C3
C6
1
1
C1
C4
Power-up (Self-test accomplished)
No start-up (1)
Power-up (Self-test accomplished)
Guard closed
Guard closed
No start-up (1)
Function 1
Guard
closed
Function 2
Guard
closed
S1
S4
Logic
channel 1
Logic
channel 2
I1
I4
Characteristics:
page 2/107
Open
Open
C2
(continued)
C5
Guard
open
Guard
open
S2
S5
I5
I2
Start
Start
Function 1
Function 2
Function 1
Function 2
F1
F2
Guard closed
Guard closed
(F2)
(F1)
(F2)
K11
K12
(F1)
K21
K22
I6
I3
S3
S6
ESC
ESC
F1
F2
K3
K4
K1
K2
Safety automation system solutions
Preventa™ safety controllers type XPSMP
With pre-defined functions
References:
page 2/108
(1)
Function 1 Function 1
K11
13
14
(3) Function 2 safety outputs.
ESC = External start conditions.
Configuration 5
Unmonitored start
Key
End of travel 1 C1-I1,
(C4-I4)
End of travel 2 C2-I2,
(C5-I5)
Start button C3-I3,
(C6-I6)
N.O. output 13-14/23-24/
33-34, (43-44/53-54/63-64)
Signalling output Y84,
(Y94)
(1) Prevention of start-up necessary: to check the sensors connected, open and
24
reclose the guard.
23
K12
(2)
0
33
34
Function 2 Function 2
Dimensions:
page 2/109
K21
1
43
44
Power-up (Self-test accomplished)
No start-up (1)
Guard closed
53
54
K22
(3)
63
64
Y
Guard
open
+
Y74
XPS MP
Wiring Diagrams:
page 2/110 to 2/117
Y84
Guard closed
Y94
To PLC
Related parts for XPSBF1132P
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
SCREW SOCKET (OT08PC)
Manufacturer:
Crouzet USA
Datasheet:
Part Number:
Description:
PANEL PLATE FOR 813
Manufacturer:
Crouzet USA
Datasheet:
Part Number:
Description:
Controller; CTD46 Dual Display Temperature, 1/16 DIN, NEMA 4X, 110/220VAC
Manufacturer:
Crouzet USA
Datasheet:
Part Number:
Description:
11R1084
Manufacturer:
Crouzet USA
Datasheet:
Part Number:
Description:
11R1086
Manufacturer:
Crouzet USA
Datasheet:
Part Number:
Description:
11R1087
Manufacturer:
Crouzet USA
Datasheet:
Part Number:
Description:
11R1089
Manufacturer:
Crouzet USA
Datasheet:
Part Number:
Description:
11R1078
Manufacturer:
Crouzet USA
Datasheet:
Part Number:
Description:
11R1079
Manufacturer:
Crouzet USA
Datasheet: