ATV12H075M2 Crouzet USA, ATV12H075M2 Datasheet - Page 29

11R1089

ATV12H075M2

Manufacturer Part Number
ATV12H075M2
Description
11R1089
Manufacturer
Crouzet USA
Datasheets

Specifications of ATV12H075M2

No. Of Phases
Single
Power Rating
0.75kW
Output Voltage Max
230V
Frequency Range
0.5 To 400Hz
Output Current
4.2A
Supply Voltage Max
230V
Rohs Compliant
Yes
Functions
ATV12H075M2 with door on
front panel closed with protective
cover 5: STOP/RESET and
RUN buttons not accessible
ATV12H075M2 with door on front
panel closed without protective
cover 5: STOP/RESET and RUN
buttons accessible
ATV12H075M2 with door on
front panel open
3 operating modes “REF”, “MON” and “CONF”
Introduction:
page 8
CONF
5
configuration
Parameter
MODE
2
2
ConF
2
5
(continued)
1
3
4
5
6
1
3
4
3
6
Reference
MODE
1
3
4
3
Specifications:
page 10
MON
REF
parameters
Monitoring
MODE
Mon
rEF
Altivar
variable speed drives
The Altivar
adjustment for the majority of applications.
Factory-set configuration:
Display: Displays the motor frequency reference
Standard motor frequency: 50 Hz
Motor supply voltage: 230 V three-phase
Acceleration and deceleration ramp times: 3 s
Low speed: 0 Hz
High speed: 50 Hz
Motor control profile: Standard (voltage/frequency)
Slip compensation: 100%
Motor thermal current: Same as the nominal motor current
DC injection: 0.7 x nominal motor current for 0.5 s
Switching frequency: 4 kHz
Automatic adaptation of deceleration ramp
2-wire transition detection control: Logic input LI1 is assigned to forward,
logic inputs LI2, LI3 and LI4 are not assigned
Logic output LO+: Not assigned
Analog input AI1: 5 V (speed reference)
Analog output AO1: Not assigned
Fault relay R1: 1 N/O contact (R1A, R1C) which opens in the event of a fault or when
the drive is powered down
1
4-digit display
Display of numeric values and codes
Unit rating of displayed value
2
“REF”: Reference mode. This mode is used to display the motor frequency
reference of the active reference channel (terminals, local mode, remote display
terminal or Modbus
the navigation button 4, if the function has been configured.
“MON”: Monitoring mode. This mode is used to display the monitoring parameters.
“CONF”: Configuration mode. This mode is used to configure the drive parameters.
It offers direct access to the “MyMenu” menu which includes the 9 most commonly
used parameters in standard applications. This list can be modified using the
SoMove setup software and can contain up to 25 parameters.
All configurable parameters can also be accessed with the “Full” menu for
applications requiring further adjustment.
3
“MODE”: Selects one of the following modes:
v “REF” reference mode
v “MON” monitoring mode
v “CONF” configuration mode
Note: This button cannot be accessed when the door on the front panel is closed.
“ESC”: Aborts a value, a parameter or a menu to return to the previous selection.
“STOP/RESET”: Controls motor stopping and drive fault clearing locally; button
active in factory-set configuration.
“RUN”: Controls motor operation locally, if it has been programmed as active.
4
Rotation: Increases or decreases the parameter value, goes to the next parameter
and can also be used to switch from one mode to another.
Press: Saves the current value, selects the value.
Option of using the button as a potentiometer in local mode.
5
RUN buttons
6
References:
page 14
Factory-set drive configuration
Human/Machine Interface (HMI)
Description
Display:
Display of drive status:
Using the buttons:
Using the navigation button:
Protective cover which can be removed to allow access to the STOP/RESET and
Mechanical lock for locking the door on the front panel
®
12 drive is configured to allow immediate start-up without any
®
®
12
serial link). In local mode, the reference can be modified using
Dimensions:
page 18
Connections:
page 22
27
10
1
2
3
4
5
6
7
8
9

Related parts for ATV12H075M2