SFH 3410 -1/2 OSRAM Opto Semiconductors Inc, SFH 3410 -1/2 Datasheet - Page 7

no-image

SFH 3410 -1/2

Manufacturer Part Number
SFH 3410 -1/2
Description
Manufacturer
OSRAM Opto Semiconductors Inc
Datasheet

Specifications of SFH 3410 -1/2

Phototransistor Type
Phototransistor
Polarity
NPN
Number Of Elements
1
Emitter-collector Voltage (max)
500mV
Collector-emitter Voltage
5.5V
Collector Current (dc) (max)
20mA
Collector-emitter Sat Volt (max)
0.1V
Dark Current (max)
3nA
Light Current
6.3/10uA
Peak Wavelength
570nm
Half-intensity Angle
120deg
Operating Temp Range
-40C to 100C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
3
Package Type
SMT
Lead Free Status / Rohs Status
Compliant
SFH 3410
Published by
OSRAM Opto Semiconductors GmbH
Wernerwerkstrasse 2, D-93049 Regensburg
www.osram-os.com
© All Rights Reserved.
The information describes the type of component and shall not be considered as assured characteristics.
Terms of delivery and rights to change design reserved. Due to technical requirements components may contain
dangerous substances. For information on the types in question please contact our Sales Organization.
Packing
Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office.
By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing
material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs
incurred.
Components used in life-support devices or systems must be expressly authorized for such purpose! Critical
1
2
components
, may only be used in life-support devices or systems
with the express written approval of OSRAM OS.
1
A critical component is a component usedin a life-support device or system whose failure can reasonably be expected
to cause the failure of that life-support device or system, or to affect its safety or effectiveness of that device or system.
2
Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain
and sustain human life. If they fail, it is reasonable to assume that the health of the user may be endangered.
2009-12-17
7

Related parts for SFH 3410 -1/2