V48B24C250BS3 Vicor Corporation, V48B24C250BS3 Datasheet
V48B24C250BS3
Available stocks
Related parts for V48B24C250BS3
V48B24C250BS3 Summary of contents
Page 1
RoHS Compliant (with pin option) DC input range Input surge withstand: 100 V for 100 ms DC output: 2 – Programmable output 110% Regulation: ±0.2% no load to full ...
Page 2
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate. Operating input voltage 36 Input surge withstand ...
Page 3
Primary Control Parallel) PC bias voltage 5.50 current limit 1.5 PC module disable 2.3 PC module enable delay PC module alarm PR emitter amplitude 5.7 PR emitter current 150 PR receiver impedance 375 PR receiver threshold ...
Page 4
Efficiency 74.5 Ripple and noise Output OVP setpoint 2.7 Dissipation, standby Load regulation Load current 0 Current limit 51 Short circuit current 5 Efficiency 81 Ripple and noise Output OVP setpoint 4.14 Dissipation, standby Load regulation Load current 0 Current ...
Page 5
Efficiency 88 Ripple and noise Output OVP setpoint 27.1 Dissipation, standby Load regulation Load current 0 Current limit 10.7 Short circuit current 7.35 Efficiency 88.5 Ripple and noise Output OVP setpoint 31.5 Dissipation, standby Load regulation Load current 0 Current ...
Page 6
The module may be disabled by pulling PC below 2.3 V with respect to the –Input. This may be done with an open collector transistor, relay, or optocoupler. Multiple converters may be disabled with a single transistor or relay either ...
Page 7
The output voltage of the converter can be adjusted or programmed via fixed resistors, potentiometers or voltage DACs. See Figures 7 and 8. +Out +S Error SC Amp –S 1kΩ 0.033 μF –Out 1.23V 1,000 Vout R (ohms ...
Page 8
The PR pin supports paralleling for increased power with N+1 (N+M) redundancy and phased array capability. Modules of the same input voltage, output voltage, and power level will current share if all PR pins are suitably interfaced. Compatible interface architectures ...
Page 9
The +Out and –Out power buses +In +Out Module –S –S –In –Out • The +Sense pins should be tied +S +In +Out Module SC Load 2 PR –S –S ...
Page 10
No. Function Label 1 +In + Primary 2 PC Control 0.23 (REF) 3 Parallel PR 5,8 4 –In – 0.300 ±0.015 7,62 ±0,38 5 –Out – Pin –Sense –S 0.300 ±0.015 7,62 ±0,38 Secondary 7 SC Control ...
Page 11
Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or maintenance. Vicor ...