PKF5113SI Ericsson Microelectronics, PKF5113SI Datasheet
PKF5113SI
Available stocks
Related parts for PKF5113SI
PKF5113SI Summary of contents
Page 1
SMD with ultra-low component height 8.0 mm (0.315 in.) • 81% effi ciency at full load • 1,500 Vdc isolation at full load • Switching frequency synchronization • MTBF >10 million hours at +50°C case temperature • Low EMI ...
Page 2
Absolute Maximum Ratings Characteristics T Case temperature at full output power C T Storage temperature S V Continuous input voltage 1) I Isolation voltage V ISO (input to output test voltage) W Transient input energy tr V Remote control voltage ...
Page 3
Safety The PKF 5113 I DC/DC power module meets the requirements of UL/EN 60 950, Safety of information technology equipment including electrical business equipment. The PKF power modules are recognized by UL and meet the applicable requirements in UL 1950 ...
Page 4
Output T = –30…+95 ° 18...75 V and pin 8 connected to pin 9, unless otherwise specifi ed Characteristics Conditions Output voltage initial setting and accuracy Output adjust range Output voltage Long ...
Page 5
Typical Characteristics Effi ciency (typ +25° 0,0 0,2 0,4 0,6 0,8 Load current (A) Temperature coeffi cient 12.2 38 ...
Page 6
Radiated EMS (Electro-Magnetic Fields) Radiated EMS is measured according to test methods in IEC Stand ard publ. 801-3. No deviation outside the V tolerance band will occur under the following conditions: Frequency range Voltage level 0.01...200 MHz ...
Page 7
Output Voltage Adjust (V ) adj Output voltage can be adjusted by using an external O resistor or other external circuitry. If other circuitry is used, the slew rate has to be limited to maximum 5 V/ms. If ...
Page 8
Ericsson Power Modules Månskärsvägen 9 SE-141 75 KUNGENS KURVA Phone: +46 8 568 69620 www.ericsson.com/powermodules Information given in this data sheet is believed to be accurate and reliable spon si bil assumed for the con ...