V300C3V3M75B Vicor Corporation, V300C3V3M75B Datasheet - Page 4

no-image

V300C3V3M75B

Manufacturer Part Number
V300C3V3M75B
Description
Manufacturer
Vicor Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
V300C3V3M75BL
Manufacturer:
EUPEC
Quantity:
134
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
CONTROL FUNCTIONS - PC PIN
Module Enable/Disable
The module may be disabled by pulling PC below 2.3V with
respect to the –Input. This may be done with an open collector
transistor, relay, or optocoupler. Multiple converters may be
disabled with a single transistor or relay either directly or via
“OR’ing” diodes. See Figure 1.
Primary Auxiliary Supply
At 5.7V, PC can source up to 1.5mA. In the example shown in
Figure 3, PC powers a “green” module enabled LED.
Figure 1—Module enable/disable.
Figure 3—LED on-state indicator.
Figure 5—Isolated on-state indicator.
Enabled"
"Module
Disable = PC <2.3V
Optocoupler
Disable
4k
4k
Set your site on VICOR at www.vicorpower.com
+In
PC
PR
–In
+In
PC
PR
–In
+In
PC
PR
–In
V300C3V3C75B DC-DC Converter
Module Alarm
The module contains “watchdog” circuitry which monitors
input voltage, operating temperature and internal operating
parameters. In the event that any of these parameters are
outside of their allowable operating range, the module will shut
down and PC will go low. PC will periodically go high and the
module will check to see if the fault (as an example,
overtemperature) has cleared. If the fault has not been cleared,
PC will go low again and the cycle will restart. The SC pin will
go low in the event of a fault and return to its normal state after
the fault has been cleared. See Figures 2 and 4.
Figure 2—PC/SC module alarm logic.
Figure 4—PC/SC module alarm timing.
Figure 6—Secondary side on-state indicator.
Fault
PC
SC
1.23V
5.7V
+In
PC
PR
–In
SW1
+Out
–Out
(0-3mA)
5.7Vdc
SC
2-20ms typ.
SW1, 2, & 3 shown
f(V
in "Fault" position
Restart
Auto
IN
)
40 s typ.
2-20ms typ.
1.00V
SW2
Input Undervoltage
Input Overvoltage
Over Temperature
Module Faults
50
SW3
1.23
Vdc
Rev. 3
1K
6K
Alarm
+Out
–Out
SC
Page 4 of 8

Related parts for V300C3V3M75B