Specifications Contd.
Notes
1
2
3
4
5
6
7
8
Nominal line, at no load.
Low line to high line at full load.
Full load to no-load at nominal line.
For conducted noise operation of the BXA40 to VDE0871, VDE0878 and
EN55022 level B, see BXA40 Design Note 101.
Reverse voltage protection can be implemented by putting a slow blow fuse on
the positive input rail. Rate the fuse at 200 Vdc,1.5 A for 48 Vdc inputs and 100
V, 4.5 A for 24 Vdc input units.
The maximum operating ambient temperature, without derating depends on
internal power dissipation and hence efficiency and cooling method. Download
BXA40 Design Note 101 which provides detailed thermal calculations and
design-in hints from the Artesyn website.
Do not exceed a dv/dt rate of 100 V per second at the trim pin input if output
current is less than 0.4% lo max.
Remote sense is offered as standard on the 2.9 V and 3.3 V products. The
BXA40-24S05J and BXA40-48S05J come with remote sense as an option.
Remote sense design is designated by the suffix ‘-S’ e.g. BXA40-48S05-SMJ (for
units with metric inserts), BXA40-48S05-SJ (for units with imperial inserts). For
models without remote sense option, pin 5 and pin 6 are absent.
18-36 Vdc
18-36 Vdc
36-75 Vdc
36-75 Vdc
36-75 Vdc
VOLTAGE
INPUT
PIN NUMBER
1
2
3
4
5
6
7
8
9
VOLTAGE
OUTPUT
3.3 V
2.9 V
12 V
5 V
5 V
PIN CONNECTIONS
CURRENT (MAX.)
OUTPUT
6.9 A
8.0 A
3.3 A
7 A
8 A
SINGLE OUTPUT
No Connection
+ Sense
Common
- Sense
+ Output
Control
+ Input
– Input
Trim
(8)
(8)
CURRENT
INPUT
70 mA
40 mA
40 mA
30 mA
30 mA
(1)
EFFICIENCY
9
10 For 2.9 V output, no short circuit protection above 90
11 Transient response, 25% to 100% load, 10% for 2.9 V and 3.3 V models.
12 Units with the suffix ‘-M’ at the end of the model number are offered as
13 An external filter capacitor is necessary for safe operation of the 24 V input
14 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
15 NOTICE: Some models do not support all options. Please contact your local
TYPICAL
EXTERNAL OUTPUT TRIMMING
Output can be externally trimmed
by ±10% using either method shown below.
75%
81%
77%
82%
87%
Overvoltage protection is 118% on 3.3 V output model.
standard with metric threaded inserts (M3). To order units with imperial
threaded inserts (4-40 UNC) please remove the suffix ‘-M’ from the model
number. These inserts are used for bolting the unit to a PCB and/or fixing
heatsinks.
models. It is also suggested that an external filter capacitor be used on the 48 V
input models. A 4 μF (or greater) film capacitor such as: ITW Paktron Capstick
series, part number 405K100CS4 4 μF/100 V is recommended, if filtering is not
used. See BXA40 Design Note 101.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special
request, please contact your local sales representative for details.
Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
LINE
0.3%
0.3%
0.3%
0.3%
0.3%
7
9
8
DOWN
REGULATION
TRIM
(2)
TRIM
UP
RT1
RT2
OR
LOAD
1.0%
1.0%
1.0%
1.0%
1.0%
7
9
8
Embedded Power for
Business-Critical Continuity
(3)
BXA40-24S3V3-SMJ
BXA40-48S2V9-SMJ
TRIMPOT
BXA40-24S05-MJ
BXA40-48S05-MJ
10KΩ
°
BXA40-48S12-MJ
C baseplate temp.
NUMBER
MODEL
(12,14,15)
(8)
(8)
(8)
(8)
Rev.03.08.07