JW100G Lineage Power, JW100G Datasheet - Page 11

no-image

JW100G

Manufacturer Part Number
JW100G
Description
Manufacturer
Lineage Power
Datasheet
Data Sheet
March 2008
Feature Descriptions
Output Voltage Set-Point Adjustment
(Trim)
Figure 20. Circuit Configuration to Decrease
Figure 21. Circuit Configuration to Increase
Output Overvoltage Protection
The output overvoltage clamp consists of control cir-
cuitry, independent of the primary regulation loop, that
monitors the voltage on the output terminals. The con-
trol loop of the clamp has a higher voltage set point
than the primary loop (see Feature Specifications
table). This provides a redundant voltage control that
reduces the risk of output overvoltage.
Lineage Power
V
ON/OFF
CASE
V
V
ON/OFF
CASE
V
I
I
I
I
(+)
(–)
(+)
(–)
(continued)
Output Voltage
Output Voltage
SENSE(+)
SENSE(+)
SENSE(–)
SENSE(–)
V
V
V
V
TRIM
TRIM
O
O
O
O
(+)
(–)
(+)
(–)
(continued)
R
R
adj-down
adj-up
JW100G and JW150G Power Modules; dc-dc Converters:
R
R
36 Vdc to 75 Vdc Input, 2.5 Vdc Output; 50 W to 75 W
LOAD
LOAD
8-748 (F).b
8-715 (F).b
Thermal Considerations
Introduction
The power modules operate in a variety of thermal
environments; however, sufficient cooling should be
provided to help ensure reliable operation of the unit.
Heat-dissipating components inside the unit are ther-
mally coupled to the case. Heat is removed by conduc-
tion, convection, and radiation to the surrounding
environment. Proper cooling can be verified by mea-
suring the case temperature. Peak temperature (T
occurs at the position indicated in Figure 22.
Note: Top view, pin locations are for reference only.
Figure 22. Case Temperature Measurement
The temperature at this location should not exceed
100 °C. The output power of the module should not
exceed the rated power for the module as listed in the
Ordering Information table.
Although the maximum case temperature of the power
module is 100 °C, you can limit this temperature to a
lower value for extremely high reliability.
For additional information on these modules, refer to
the Thermal Management JC-, JFC-, JW-, and JFW-
Series 50 W to 150 W Board-Mounted Power Modules
Technical Note (TN97-008EPS).
7.6 (0.30)
Measurements shown in millimeters and (inches).
Location
V
ON/OFF
CASE
V
I
I
(+)
(–)
38.0 (1.50)
+ SEN
– SEN
V
TRIM
V
O
O
(+)
(–)
MEASURE CASE
TEMPERATURE HERE
8-716 (F).f
C
)
11

Related parts for JW100G