MAX9546ESA+ Maxim Integrated Products, MAX9546ESA+ Datasheet - Page 13

no-image

MAX9546ESA+

Manufacturer Part Number
MAX9546ESA+
Description
IC VIDEO INTERFACE DIFF 8-SOIC
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX9546ESA+

Applications
Driver
Output Type
Differential
Number Of Circuits
1
-3db Bandwidth
18MHz
Slew Rate
70 V/µs
Current - Supply
64mA
Voltage - Supply, Single/dual (±)
7.5 V ~ 10 V
Mounting Type
Surface Mount
Package / Case
8-SOIC (0.154", 3.90mm Width) Exposed Pad
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
As with all Maxim devices, ESD-protection structures
are incorporated on all pins to protect against electro-
static discharges encountered during handling and
assembly. The driver outputs and receiver inputs have
extra protection against static electricity. Maxim’s engi-
neers developed state-of-the-art structures to protect
these pins against ESD of ±15kV without damage. The
ESD structures withstand high ESD in all states: normal
operation and powered down. After an ESD event, the
MAX9546/MAX9547 keep working without latchup. ESD
protection can be tested in various ways; the driver out-
puts and receiver inputs of this product family are char-
acterized for protection to ±15kV using the Human
Body Model. Other ESD test methodologies include IEC
Figure 5. Human Body ESD Test Model
VOLTAGE
SOURCE
HIGH-
DC
CHARGE-CURRENT-
LIMIT RESISTOR
1MΩ
R
C
100pF
______________________________________________________________________________________
C s
STORAGE
CAPACITOR
RESISTANCE
DISCHARGE
1.5kΩ
±15kV ESD Protection
R
D
Differential Video Interface Chipset
DEVICE
UNDER
TEST
1000-4-2 Contact Discharge and IEC 1000-4-2 Air-Gap
Discharge (formerly IEC 801-2).
ESD performance depends on a variety of conditions.
Contact Maxim for a reliability report that documents
test setup, test methodology, and test results.
Figure 5 shows the Human Body Model, and Figure 6
shows the current waveform it generates when dis-
charged into a low impedance. This model consists of
a 100pF capacitor charged to the ESD voltage of inter-
est, which is then discharged into the test device
through a 1.5kΩ resistor.
Figure 6. Human Body Current Waveform
AMPERES
I
P
36.8%
100%
90%
10%
0
0
t
RL
CURRENT WAVEFORM
TIME
t
DL
I r
ESD Test Conditions
Human Body Model
PEAK-TO-PEAK RINGING
(NOT DRAWN TO SCALE)
13