AT89C51CC03 Atmel Corporation, AT89C51CC03 Datasheet - Page 7

no-image

AT89C51CC03

Manufacturer Part Number
AT89C51CC03
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of AT89C51CC03

Flash (kbytes)
64 Kbytes
Max. Operating Frequency
40 MHz
Cpu
8051-12C
Max I/o Pins
37
Spi
1
Uart
1
Can
1
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
62.5
Sram (kbytes)
2.25
Eeprom (bytes)
2048
Self Program Memory
API
Operating Voltage (vcc)
3.0 to 5.5
Timers
4
Isp
UART/CAN
Watchdog
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT89C51CC03C-7CTIM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51CC03C-IM
Manufacturer:
AT
Quantity:
17
Part Number:
AT89C51CC03C-RDRIM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51CC03C-RLRIM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51CC03C-RLTIM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51CC03C-S3RIM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51CC03CA-IM
Manufacturer:
TI
Quantity:
18
Part Number:
AT89C51CC03CA-JM
Manufacturer:
ATEML
Quantity:
42
Part Number:
AT89C51CC03CA-RDTUM
Manufacturer:
COSMO
Quantity:
6 000
Part Number:
AT89C51CC03CA-RLTUM
Manufacturer:
ADI
Quantity:
141
Physical Layer
Frame Description
4266C–CAN–03/08
The UART used to transmit information has the following configuration:
The Serial Protocol is based on the Intel Hex-type records.
Intel Hex records consist of ASCII characters used to represent hexadecimal values and are
summarized below.
Table 1. Intel Hex Type Frame
Character: 8-bit data
Parity: none
Stop: 2 bits
Flow control: none
Baud rate: autobaud is performed by the bootloader to compute the baud rate chosen by the
host.
Record Mark:
Record length:
Load Offset:
Record Type:
Data/Info:
Checksum:
Record Mark is the start of frame. This field must contain ’:’.
Record length specifies the number of Bytes of information or data which follows the
Record Type field of the record.
Load Offset specifies the 16-bit starting load offset of the data Bytes, therefore this
field is used only for
Data Program Record.
Record Type specifies the command type. This field is used to interpret the
remaining information within the frame.
Data/Info is a variable length field. It consists of zero or more Bytes encoded as pairs
of hexadecimal digits. The meaning of data depends on the Record Type.
The two’s complement of the 8-bit Bytes that result from converting each pair of
ASCII hexadecimal digits to one Byte of binary, and including the Record Length field
to and including the last Byte of the Data/Info field. Therefore, the sum of all the
ASCII pairs in a record after converting to binary, from the Record Length field to and
including the Checksum field, is zero.
Record Mark ‘:’
1 byte
Record length
1 byte
AT89C51CC03 UART Bootloader
Load Offset
2 bytes
Record Type
1 bytes
Data or Info
n byte
Checksum
1 byte
7