AD7799 Analog Devices, AD7799 Datasheet - Page 21

no-image

AD7799

Manufacturer Part Number
AD7799
Description
3-Channel, Low Noise, Low Power, 24-Bit, Sigma Delta ADC with On-Chip In-Amp
Manufacturer
Analog Devices
Datasheet

Specifications of AD7799

Resolution (bits)
24bit
# Chan
3
Sample Rate
n/a
Interface
Ser,SPI
Analog Input Type
Diff-Uni
Ain Range
(2Vref/PGA Gain) p-p
Adc Architecture
Sigma-Delta
Pkg Type
SOP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7799BRU
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7799BRUZ
Manufacturer:
ADI
Quantity:
2 500
Part Number:
AD7799BRUZ
Manufacturer:
ADI
Quantity:
1 000
Part Number:
AD7799BRUZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7799BRUZ-REEL
Manufacturer:
ADI
Quantity:
1 000
Part Number:
AD7799BRUZ-REEL
Manufacturer:
AD
Quantity:
800
Part Number:
AD7799BRUZ-REEL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7799BRUZREEL
Manufacturer:
PH
Quantity:
6 469
Continuous Read
Rather than write to the communication register to access the
data each time a conversion is complete, the AD7798/AD7799
can be configured so that the conversions are placed on the
DOUT/ RDY line automatically. By writing 01011100 to the
communication register, the user need only apply the
appropriate number of SCLK cycles to the ADC, and the
16-/24-bit word is automatically placed on the DOUT/ RDY line
when a conversion is complete. The ADC should be configured
for continuous conversion mode.
When DOUT/ RDY goes low to indicate the end of a conversion,
sufficient SCLK cycles must be applied to the ADC, and the
data conversion is placed on the DOUT/ RDY line. When the
conversion is read, DOUT/ RDY returns high until the next
conversion is available. In this mode, the data can only be read
once. In addition, the user must ensure that the data-word is
DOUT/RDY
SCLK
DIN
CS
0x5C
Figure 18. Continuous Read
Rev. A | Page 21 of 28
DATA
read before the next conversion is complete. If the user does not
read the conversion before the completion of the next conversion,
or if insufficient serial clocks are applied to the AD7798/AD7799
to read the word, the serial output register is reset when the
next conversion is complete, and the new conversion is placed
in the output serial register.
To exit the continuous-read mode, the instruction 01011000
must be written to the communication register while the
DOUT/ RDY pin is low. While in continuous-read mode, the
ADC monitors activity on the DIN line in case the instruction
to exit the continuous-read mode occurs. Additionally, a reset
occurs if 32 consecutive 1s are seen on DIN. Therefore, DIN
should be held low in continuous-read mode until an
instruction is written to the device.
DATA
AD7798/AD7799
DATA

Related parts for AD7799