ADP8860 Analog Devices, ADP8860 Datasheet - Page 38

no-image

ADP8860

Manufacturer Part Number
ADP8860
Description
Charge Pump, 7-Channel Smart LED Driver with I2C Interface
Manufacturer
Analog Devices
Datasheet

Specifications of ADP8860

Vin Range
2.4V to 5.5V
Vout (v)
4.3 to 5.5
Synchronous
No
Package
20-Lead WLCSP
Led Configuration
Parallel
Topology
Capacitive
I2c Support
Yes
Max Iout (ma)
60mA
Brightness Control
I2C
Peak Efficiency (%)
89%
Switching Frequency
1MHz

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADP8860ACBZ-R7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADP8860ACPZ
Manufacturer:
SPECTR
Quantity:
10 400
Part Number:
ADP8860BCBZ-R7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADP8860XCBZ-R7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ADP8860
Bit Name
SC4_EN
SC3_EN
SC2_EN
SC1_EN
Independent Sink Current Time (ISCT1)—Register 0x11
Table 43. ISCT1 Bit Map
Bit 7
Table 44. Bit Descriptions for the ISCT1 Register
Bit Name
SCON
SC7OFF
SC6OFF
SC5OFF
1
2
An independent sink remains on continuously when SCx_EN = 1 and SCx_OFF is 00 (disabled).
To enable multiple independent sinks, set the appropriate SCx_EN bits. To create equivalent blinking and fading sequences, enable all independent sinks in one write
cycle to cause a preprogrammed sequence to start simultaneously.
Bit No.
7:6
5:4
3:2
1:0
SCON
Bit 6
Description
SC on time. If the SCxOFF time is not disabled, then when the independent current sink is enabled (Register 0x10) it
remains on for the on time selected (per the following list) and then turns off.
00 = 0.2 sec.
01 = 0.6 sec.
10 = 0.8 sec.
11 = 1.2 sec.
SC7 off time. When the SC off time is disabled, the ISC remains on while enabled. When the SC off time is set to any
other value, the ISC turns off for the off time (per the following listed times) and then turns on according to the SCON
setting.
00 = off time disabled.
01 = 0.6 sec.
10 = 1.2 sec.
11 = 1.8 sec.
SC6 off time. When the SC off time is disabled, the ISC remains on while enabled. When the SC off time is set to any
other value, the ISC turns off for the off time (per the following listed times) and then turns on according to the SCON
setting.
00 = off time disabled.
01 = 0.6 sec.
10 = 1.2 sec.
11 = 1.8 sec.
SC5 off time. When the SC off time is disabled, the ISC remains on while enabled. When the SC off time is set to any
other value, the ISC turns off for the off time (per the following listed times) and then turns on according to the SCON
setting.
00 = off time disabled.
01 = 0.6 sec.
10 = 1.2 sec.
11 = 1.8 sec.
3
Bit No.
2
1
0
1, 2
Bit 5
SC7OFF
Bit 4
Description
This enable acts upon the LED4.
1 = SC4 is turned on.
0 = SC4 is turned off.
This enable acts upon the LED3.
1 = SC3 is turned on.
0 = SC3 is turned off.
This enable acts upon the LED2.
1 = SC2 is turned on.
0 = SC2 is turned off.
This enable acts upon the LED1.
1 = SC1 is turned on.
0 = SC1 is turned off.
Rev. 0 | Page 38 of 52
Bit 3
SC6OFF
Bit 2
Bit 1
SC5OFF
Bit 0

Related parts for ADP8860