9-776633-8 TE Connectivity, 9-776633-8 Datasheet
9-776633-8
Specifications of 9-776633-8
Related parts for 9-776633-8
9-776633-8 Summary of contents
Page 1
... Product Specification (.040II/.070II Hybrid I/O Connector MK-II for Wire-to-Board ! Termination) 109-5000: Test Specification (General Requirements for Test Specification) ! 114-5159: Application Specification (Crimping .040II Series Tab and Receptacle Contact) ! 114-5160: Application Specification (Crimping .070II Series Tab and Receptacle Contact) ! 114-5198: Application Specification (Crimping .070III Unsealed Contact, Receptacle) ! 501-5303: Qualification Test Report ( ...
Page 2
... AMP Spec 109-5301. Impressed voltage 500 volts DC. Test between adjacent circuits of mated connectors. AMP Spec 109-5302. 12 volts DC impressed 1 minute. AMP Spec 109-5312. Measure temperature rise by energized current. AMP Spec 109-5310. Applied current per Figures 6 and 7. 45 minutes ON, 15 minutes OFF, 200 cycles. ...
Page 3
... III: 10 milliohms maximum final. .040II: 5.8 N maximum. .070II, III: 10 milliohms maximum final. .040II: 0.98 N minimum for silver plating; 0.69 N minimum for gold plating. .070II, III: 0.98 N minimum for silver plating; 0.69 N minimum for gold plating. 10 position maximum. 12 position maximum. 16 position maximum. ...
Page 4
... Secondary Lock 3.5.19 Crimp Tensile Strength 3.5.20 Durability, Repeated Mating/Unmating 3.5.21 Resistance to “Kojiri” 3.5.22 Solderability 3.5.23 Handling Ergonomics 3.5.24 Double Lock Plate Locking Strength 3.5.25 Thermal Shock Rev A Requirement 9.8 N maximum per contact minimum minimum. Wire Size Crimp Tensile Operation speed: 100 mm per 2 mm AWG N minimum 0 ...
Page 5
... AMP Spec 109-5105. SO gas: 10 ppm, 95% RH hours. / AMP Spec 109-5107. 120 C , 120 hours. / AMP Spec 109-5104. -50 ± 120 hours. / AMP Spec 109-5108. Subject JIS R5210 cement blow of 1.5 kg per 10 seconds in 15 minute intervals for 90 minutes. AMP Spec 109-5110 ...
Page 6
... Humidity, Steady State Industrial Gas Temperature Life, Heat Aging Resistance to Cold Dust Bombardment (a) Numbers indicate sequence in which tests are performed. Rev A Test Group Test Sequence ( 1,19 1,11 1, 3,5,7 3,6,8 3,6,8 3,6,8,10 2,7,9,14 3,6 2,10 2, Figure 2 108-5342 ...
Page 7
... From the measured readings, deduct the resistance of the 150 mm long wire used for termination. When testing for rated current measurement, apply 12 volts DC, 1 ampere to the circuit. For obtaining uniformity of the current density on the probing points Y Y’, apply soldering on the probing points prior to testing. ...
Page 8
... Coefficient 1 1 2-3 0.75 4-5 0.6 6-8 0.55 9-12 0.5 13- 0.4 Figure 7 Current applied to all positions max Current applied to every other position in multiple connector Test Method I Test Current Duration Test Current (amperes) (minutes) (amperes Figure 8 108-5342 Test Method II Duration (minutes 110 5 170 250 ...
Page 9
... Rev A Figure 9 Figure 10 Figure 11 108-5342 ...
Page 10
Rev A APPENDIX 108-5342 ...
Page 11
... Hybrid I/O connector 26 position low profile cap housing assembly 638207 .040/.070 Hybrid I/O connector 10 position plug housing assembly 1438794 .040/.070 Hybrid I/O connector 10 position plug housing assembly 987989 .040/.070 Hybrid I/O connector 22 position plug housing assembly 638211 .040/.070 Hybrid I/O connector 32 position cap housing assembly, vertical 776629 ...
Page 12
... S receptacle contact (pre-tin) 175266 .040II S receptacle contact (selective gold) 175268 .070II S receptacle contact (pre-tin) 175275 .070II S receptacle contact (selective gold) 175269 .070II M receptacle contact (pre-tin) 175276 .070II M receptacle contact (selective gold) 1318629 .070III ML receptacle contact (pre-tin) Rev A Product Description 108-5342 ...