ST72334J4 STMicroelectronics, ST72334J4 Datasheet - Page 124

no-image

ST72334J4

Manufacturer Part Number
ST72334J4
Description
8-BIT MCU WITH SINGLE VOLTAGE FLASH MEMORY,ADC, 16-BIT TIMERS, SPI, SCI INTERFACES
Manufacturer
STMicroelectronics
Datasheet

Specifications of ST72334J4

Clock Sources
crystal/ceramic resonator oscillators or RC oscillators, external clock, backup Clock Security System
4 Power Saving Modes
Halt, Active-Halt, Wait and Slow
Two 16-bit Timers With
2 input captures (only one on timer A), 2 output compares (only one on timer A), External clock input on timer A, PWM and Pulse generator modes
ST72334J/N, ST72314J/N, ST72124J
EMC CHARACTERISTICS (Cont’d)
16.7.2 Absolute Electrical Sensitivity
Based on three different tests (ESD, LU and DLU)
using specific measurement methods, the product
is stressed in order to determine its performance in
terms of electrical sensitivity. For more details, re-
fer to the AN1181 ST7 application note.
16.7.2.1 Electro-Static Discharge (ESD)
Electro-Static Discharges (3 positive then 3 nega-
tive pulses separated by 1 second) are applied to
the pins of each sample according to each pin
combination. The sample size depends of the
number of supply pins of the device (3 parts*(n+1)
supply pin). Two models are usually simulated:
Human Body Model and Machine Model. This test
conforms to the JESD22-A114A/A115A standard.
See
Human Body Model Test Sequence
– C
– S1 switches position from generator to R.
– A discharge from C
– S2 must be closed 10 to 100ms after the pulse
Absolute Maximum Ratings
Figure 75. Typical Equivalent ESD Circuits
Notes:
1. Data based on characterization results, not tested in production.
124/153
ator.
to the ST7 occurs.
delivery period to ensure the ST7 is not left in
charge state. S2 must be opened at least 10ms
prior to the delivery of the next pulse.
HIGH VOLTAGE
V
V
GENERATOR
Symbol
ESD(HBM)
ESD(MM)
L
Figure 75
is loaded through S1 by the HV pulse gener-
PULSE
Electro-static discharge voltage
(Human Body Model)
Electro-static discharge voltage
(Machine Model)
and the following test sequences.
S1
L
through R (body resistance)
C
L
100pF
HUMAN BODY MODEL
Ratings
R=1500
ST7
T
T
A
A
S2
+25°C
+25°C
Machine Model Test Sequence
– C
– S1 switches position from generator to ST7.
– A discharge from C
– S2 must be closed 10 to 100ms after the pulse
– R (machine resistance), in series with S2, en-
ator.
delivery period to ensure the ST7 is not left in
charge state. S2 must be opened at least 10ms
prior to the delivery of the next pulse.
sures a slow discharge of the ST7.
HIGH VOLTAGE
GENERATOR
L
is loaded through S1 by the HV pulse gener-
Conditions
PULSE
S1
L
to the ST7 occurs.
C
L
200pF
Maximum value
MACHINE MODEL
ST7
3000
400
1)
Unit
V
S2

Related parts for ST72334J4