1-1379913-1 TE Connectivity, 1-1379913-1 Datasheet - Page 3

1-1379913-1

Manufacturer Part Number
1-1379913-1
Description
Manufacturer
TE Connectivity
Datasheets

Specifications of 1-1379913-1

Product Type
Connector
Connector Type
Housing
Sealed
No
Number Of Positions
20
Centerline, Matrix (mm [in])
2.54 x 7.0 [.100 x .275]
Staggered Centerline
Without
Contact Type
Tab
Tab Contacts
Without
2.5mm Pin Diameter Contacts
Without
Contact Style
MPQ, MQS
Number Of Mqs Contacts
16
Connector Style
Plug
Housing Color
Yellow
Housing Material
PBT - GF
Fiber Optic Contacts
Without
Retainer
Without
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not reviewed for lead free solder process
Rohs/elv Compliance History
Always was RoHS compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
1-1379913-1
Manufacturer:
N/A
Quantity:
46 372
Part Number:
1-1379913-1
Manufacturer:
TE Connectivity AMP Connectors
Quantity:
998
3. EXIGENCES ET ESSAIS - DEFINITION OF TEST
Les essais sont effectués conformément à la norme connectique CEI 60512 ou la B21 7050 rev. B ou la D11 5501
rev. A de PSA.
Test are carried according to IEC 60512 specification and standard PSA B21 7050 rev. B or PSA D11 5501 rev. A.
Examen visuel
Visual examination
Résistance d'isolement
Insulation resistance
Tension de tenue
Dielectric withstanding voltage
Résistance de contact
Contact resistance
Résistance du shunt
Shunt resistance
Rév.D
Essais - Tests
Essais - Tests
EXAMEN GÉNÉRAL - GENERAL EXAMINATION
ESSAIS ÉLECTRIQUES - ELECTRICAL TESTS
AVEC COURT-CIRCUIT POUR LIAISON FIL-FIL
20 WAYS WITH SHORT CIRCUIT
CONNECTOR WIRE TO WIRE APPLICATIONS
Examen à l’oeil nu
Examination with the naked eye
Tension d'essai : 100 V
Essai entre un contact et tous les autres
Test voltage : 100 V
Test between one contact and the others
Tension d'essai : 1000 V (+/- 50V) AC pendant
1 min (+/- 5s) entre chaque contact
Test voltage : 1000 V (+/- 50V) AC during 1 min
(+/- 5s) between each contact
Méthode au niveau des mV :
Method at mV level :
Méthode du courant nominal : la mesure est
effectuée sous intensité nominale définie
Nominal current method : the measurement is
carried out under defined nominal current
Méthode au niveau des mV :
Method at mV level :
Mesure du courant de circuit d’allumage
pyrotechnique avant et après 20 manœuvres
d’accouplement et de désaccouplement de la
connectique
Current measure of the turning on circuit before
and after 20 cycles of coupling/uncoupling
connector.
- Tension d’essai : 20 mV DC
- Courant d’essai : 100 mA max
- Test voltage : 20 mV DC
- Test current : 100 mA max
- Tension d’essai entre 1 et 16 V
- Test current between 1 and 16 V
- Tension d’essai : 20 mV DC
- Courant d’essai : 100 mA max
- Test voltage : 20 mV DC
- Test current : 100 mA max
Modalités - Modalities
Modalités - Modalities
MQS MPQ
Pas de défaut nuisant au
bon fonctionnement
No defect that would
impair normal operation
Ni claquage, ni amorce
d'arc
No breakdown, no
flashover
Rc ini < 10 mΩ
∆Rc < 10 mΩ
Rc ini < 10 mΩ
∆Rc < 10 mΩ
Rc ini < 100 mΩ
Courant du circuit
d’allumage inférieur à
0,2 A pendant 10
secondes
Current of the turning on
circuit less than 0.2 A for
10 seconds
Sanction - Decision
Sanction - Decision
Ri ≥ 100 M
108-15343
3 de 13

Related parts for 1-1379913-1