MAXQ3180 Maxim, MAXQ3180 Datasheet - Page 31

no-image

MAXQ3180

Manufacturer Part Number
MAXQ3180
Description
The MAXQ3180 is a dedicated electricity measurement front-end that collects and calculates polyphase voltage, current, power, energy, and many other metering and power-quality parameters of a polyphase load
Manufacturer
Maxim
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAXQ3180-RAN
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAXQ3180-RAN+
Manufacturer:
SANKEN
Quantity:
23 000
Part Number:
MAXQ3180-RAN+T
Manufacturer:
MAXIM
Quantity:
10
Part Number:
MAXQ3180-RBN
Manufacturer:
MAXIM/美信
Quantity:
20 000
Bit:
Name:
Reset:
BIT
2:1
7
6
5
4
3
LINFRM
WIRSYS
DHARA
DFUNA
NAME
DFUN
Low-Power, Multifunction, Polyphase AFE
______________________________________________________________________________________
7
0
Reserved.
When set, disables automatic determination of the filter parameters for the harmonic filter coefficient. If
set by the host software, the host must set a value in the A1HARM filter coefficient register to
establish the operating frequency of this filter if harmonic-mode calculations are used. When cleared,
the MAXQ3180 automatically determines the value of the harmonic-filter coefficient based on the
measured line frequency and the harmonic-order requested (AUX_CFG.ORDH).
When set, disables automatic determination of the filter parameters for the fundamental-mode filter
described above. If set by the host software, the host must set a value in the A1FUND filter coefficient
register to establish the operating frequency of this filter if fundamental-mode calculations are used.
When clear, the MAXQ3180 automatically determines the value of the fundamental-mode filter
coefficient based on the measured line frequency.
When set, fundamental-mode calculations are disabled. Fundamental-mode calculations provide
information about power and energy that are consumed only at the fundamental line frequency apart
from any harmonics that could be present. Setting this bit disables all fundamental frequency registers
but allows the MAXQ3180 to calculate other parameters at a higher rate. Set this bit when (1)
fundamental mode values do not need to be read, and (2) R_ADCRATE needs to be reduced below its
default value.
Selects the current linearity offset calibration method. See the Calibrating Current Offset section for
more information.
0 = IRMS
1 = IRMS + OFFS
These bits select the coefficient used in calculating apparent power.
00 = 1-phase, 3-wire (1P3W), or 3-phase, 4-wire (3P4W) (C = 1)
01 = 3-phase, 3-wire (3P3W) (C = 3/2)
10 = three voltages, three currents (3V3A) (C = 3/3)
3P3W Wiring (01)
DHARA
6
0
2
+ OFFS
DFUNA
5
0
DFUN
Operating Mode Register 2 (OPMODE2) (0x003)
0
4
FUNCTION
LINFRM
3
0
V
AB
2
0
V
WIRSYS
CB
I
A
I
C
1
0
APPSEL
0
0
31