MAX349 Maxim, MAX349 Datasheet - Page 4

no-image

MAX349

Manufacturer Part Number
MAX349
Description
The MAX349/MAX350 are 8-channel and dual 4-channel serially controlled multiplexers (muxes)
Manufacturer
Maxim
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX3490
Manufacturer:
TST
Quantity:
5 000
Part Number:
MAX3490AEGSA+
0
Part Number:
MAX3490AEGSA+T
0
Part Number:
MAX3490AEGSA+T0AEGSA+T
0
Part Number:
MAX3490CSA
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX3490CSA+
Manufacturer:
Maxim
Quantity:
2 800
Part Number:
MAX3490CSA+T
Manufacturer:
Maxim
Quantity:
2 500
Part Number:
MAX3490CSA+T
Manufacturer:
TI
Quantity:
3 145
Part Number:
MAX3490CSA+T
Manufacturer:
MAXIM
Quantity:
1 323
Part Number:
MAX3490CSA+T
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX3490CSA-T
Manufacturer:
MAXIM
Quantity:
4 017
Part Number:
MAX3490ECSA
Manufacturer:
MAX
Quantity:
20 000
Company:
Part Number:
MAX3490ECSA+
Quantity:
20
Part Number:
MAX3490ECSA+T
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX3490EESA
Quantity:
1 903
Part Number:
MAX3490EESA
Manufacturer:
MAXIM
Quantity:
1 000
Part Number:
MAX3490EESA
Manufacturer:
MAXIM
Quantity:
12 000
Part Number:
MAX3490EESA
Manufacturer:
MAXIM/美信
Quantity:
20 000
Serially Controlled, Low-Voltage,
8-Channel/Dual 4-Channel Multiplexers
TIMING CHARACTERISTICS—Dual Supplies (Figure 1)
(V+ = +4.5V to +5.5V, V- = -4.5V to -5.5V, T
Note 1: The algebraic convention is used in this data sheet; the most negative value is shown in the minimum column.
Note 2: ∆R
Note 3: Leakage parameters are 100% tested at maximum rated hot temperature and guaranteed by correlation at room temp.
Note 4: Guaranteed by design.
Note 5: Leakage testing at single supply is guaranteed by testing with dual supplies.
Note 6: See Figure 6. Off-isolation = 20log
Note 7: Between any two switches. See Figure 3.
4
SERIAL DIGITAL INTERFACE
SCLK Frequency
Cycle Time
CS Lead Time
CS Lag Time
SCLK High Time
SCLK Low Time
Minimum Data Setup Time
Data Hold Time
DIN Data Valid after Falling SCLK
(Note 4)
Rise Time of DOUT (Note 4)
Allowable Rise Time at DIN, SCLK
(Note 4)
Fall Time of DOUT (Note 4)
Allowable Fall Time at DIN, SCLK
(Note 4)
RESET Minimum Pulse Width
_______________________________________________________________________________________
specified voltages. Flatness is defined as the difference between the maximum and minimum value of on-resistance as
measured over the specified analog signal range.
PARAMETER
ON
= R
ON(max)
- R
ON(min)
. On-resistance match between channels and on-resistance flatness are guaranteed only with
SYMBOL
t
CH
f
t
CSH2
t
SCLK
t
t
t
t
CSS
t
t
t
t
t
SCR
t
SCF
CH
DH
DO
RW
CL
DS
DR
DF
+ t
10
A
= T
CL
V
COM
MIN
50% of SCLK to 10% of DOUT,
C
20% of V+ to 70% of V+,
C
20% of V+ to 70% of V+,
C
20% of V+ to 70% of V+,
C
20% of V+ to 70% of V+,
C
/V
L
L
L
L
L
to T
NO
= 10pF
= 10pF
= 10pF
= 10pF
= 10pF
, V
MAX
COM
, unless otherwise noted. Typical values are at T
= output. NO = input to off switch.
CONDITIONS
C, E, M
C, E, M
C, E, M
C, E, M
C, E, M
C, E, M
C, E, M
C, E, M
C, E, M
C, E, M
C, E, M
C, E, M
C, E, M
T
T
A
A
= +25°C
= +25°C
MIN
480
240
240
190
190
0
0
(Note 1)
A
TYP
-17
17
85
70
= +25°C.)
MAX
100
400
100
100
2.1
2
2
UNITS
MHz
ns
ns
ns
ns
ns
ns
ns
ns
ns
µs
ns
µs
ns

Related parts for MAX349