MAX890L Maxim, MAX890L Datasheet
MAX890L
Available stocks
Related parts for MAX890L
MAX890L Summary of contents
Page 1
... Thermal-overload pro- tection limits power dissipation and junction tempera- tures. The MAX890L’s maximum current limit is 1.2A. The cur- rent limit through the switch is programmed with a resistor from SET to ground. The quiescent supply cur- rent is a low 10µA. When the switch is off, the supply current decreases to 0.1µ ...
Page 2
... FAULT Logic Output High Leakage Current Slow-Current-Loop Response Time Fast-Current-Loop Response Time Turn-On Time Turn-Off Time 2 _______________________________________________________________________________________ Operating Temperature Range MAX890LESA ....................................................-40°C to +85°C + 0.3V) Storage Temperature Range ........................... -65°C to +150°C IN Lead Temperature (soldering, 10s) . ...............................+300°C Soldering Temperature (reflow) .......................................+260°C = +25°C.) A ...
Page 3
P-Channel Switch with Thermal Shutdown ELECTRICAL CHARACTERISTICS (V = +3V -40°C to +85°C, unless otherwise noted.) (Note PARAMETER Operating Voltage Quiescent Current Off-Supply Current Off-Switch Current Undervoltage Lockout On-Resistance Current-Limit-Amplifier Threshold Current ...
Page 4
Current-Limited, High-Side P-Channel Switch with Thermal Shutdown __________________________________________Typical Operating Characteristics (T = +25°C, unless otherwise noted.) A QUIESCENT CURRENT vs. INPUT VOLTAGE GND OUT ...
Page 5
P-Channel Switch with Thermal Shutdown ____________________________Typical Operating Characteristics (continued +25°C, unless otherwise noted.) A OUTPUT OVERLOAD (SLOW LOOP RESPONSE 0V, 0A 2μs/div C = 100μ 0.1μF IN OUT 1V/div, AC-COUPLED ...
Page 6
... I is the desired current limit. LIMIT Short-Circuit Protection The MAX890L is a short-circuit-protected switch. In the event of an output short circuit or current-overload con- dition, the current through the switch is limited by the internal current-limiting error amplifier to 1 When the fault condition is removed, the replica error ...
Page 7
... If the fault short-circuit condition is not removed, the switch cycles on and off, resulting in a pulsed output. The MAX890L provides a fault output (FAULT). This open-drain output goes low when in current limit or when the die temperature exceeds +135°C. A 100kΩ ...
Page 8
... P-Channel Switch with Thermal Shutdown REVISION REVISION NUMBER DATE Added the MAX890LESA/V+ part number to the Ordering Information, deleted the Chip 4 4/11 Information section Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied ...