TSM4002A TEAM SOURCE DISPLAY, TSM4002A Datasheet - Page 9

no-image

TSM4002A

Manufacturer Part Number
TSM4002A
Description
Manufacturer
TEAM SOURCE DISPLAY
Datasheet

Specifications of TSM4002A

Format,char X Line
40 x 2
Outline Dimension(mm)
182.0 x 33.5 x 14.0MAX.
V.a.(mm)
155.1 x 16.0
Supply Voltage
3.3V / 5.0V
Moq
1K
Team Source Display
www.tslcd.com
16.
16.
16.
Thermal Shock
5 Cycle
*
17.
17.
17.
16. Reliability
17. Functional
Wide temp. version may not available for some products, Please consult our sales engineer or respresentative.
High Temperature (Power Off)
High Temperature (Power On)
Low Temperature (Power Off)
Low Temperature (Power On)
Viewing
High Temperature & High
Angle
Operating Temperature
Reliability
Reliability
Reliability Condition
Functional
Functional
Functional Test
17.1Sample plan
17.2Inspection condition
17.3Definition of Inspection Zone in LCD
17.4Major Defect
Storage Temperature
Sample plan according to MIL-STD-105D level 2, and acceptance/rejection criteria is.
Base on :
Viewing distance for cosmetic inspection is 30cm with bare eyes, and under an
environment of 800 lus (20W) light intensity. All direction for inspecting the sample
should be within 45° against perpendicular line.
Zone A : Character / Digit area
Zone B : Viewing area except Zone A ( Zone A + Zone B = minimum Viewing area )
Zone C : Outside viewing area ( invisible area after assembly in customer’s product )
Note :
All functional defects such as open ( or missing segment ), short, contrast differential,
excess power consumption, smearing, leakage, etc. and overall outline dimension
beyond the drawing. Are classified as major defects.
Expected Lift
Humidity
A
Vertical Θ(㎜)
Condition
Condition
Condition
Horizontal Φ
Test
Test
Test & & & & Inspection
B
As a general rule, visual defects in Zone C are permissible, when it is no
trouble for quality and assembly of customer’s product.
C
Inspection
Inspection
Inspection Criteria
Major defect : AQL 0.65
C 60min@70℃
A 60min@-20℃ 60min@-35℃ 60min@-20℃ 60min@-30℃
B
Normal Temp.
50,000 Hours
55℃/90%RH
10° to 30°
5min@25℃
-10 to 70℃
-20 to 80℃
240 Hours
240 Hours
240 Hours
240 Hours
240 Hours
@-20℃
@-10℃
Criteria
Criteria
Criteria
± 30°
@70℃
@70℃
TN Type
A
50,000 Hours
75℃/90%RH
60min@90℃
Wide Temp.
10° to 30°
5min@25℃
-25 to 80℃
-35 to 90℃
240 Hours
240 Hours
240 Hours
240 Hours
240 Hours
@-35℃
@-25℃
± 30°
@90℃
@80℃
Minor defect : AQL 2.5
B
Normal Temp.
50,000 Hours
45℃/90%RH
60min@70℃
-10° to 40°
5min@25℃
-20 to 70℃
240 Hours
240 Hours
240 Hours
240 Hours
240 Hours
0 to 50℃
@-15℃
@-10℃
@65℃
@60℃
± 30°
C
STN Type
LCM Specification
50,000 Hours
65℃/90%RH
60min@80℃
-10° to 40°
Wide Temp.
5min@25℃
*
*
-20 to 70℃
-30 to 80℃
240 Hours
240 Hours
240 Hours
240 Hours
240 Hours
@-25℃
@-20℃
@75℃
@70℃
± 30°

Related parts for TSM4002A