VUB120-16NOXT IXYS, VUB120-16NOXT Datasheet

no-image

VUB120-16NOXT

Manufacturer Part Number
VUB120-16NOXT
Description
3-Phase Rectifier Bridge with Brake
Manufacturer
IXYS
Datasheet

Specifications of VUB120-16NOXT

Vrrm, Rect, (v)
1600
Idav, Rec, (a)
188
@ Th, Rect, (°c)
-
@ Tc, Rect, (°c)
80
Vces, Igbt, (v)
1200
Ic80, Igbt, (a)
107
Vrrm, Fast Diode, (v)
1200
If(av), Fast Diode, (a)
40
Trr, Fast Diode, (ns)
150
Package Style
V2-Pack
Standard Rectifier Module
3~ Rectifier Bridge + Brake Unit
Part name
VUB120-16NOXT
● Soldering connections for PCB mounting
● Convenient package outline
● NTC
IXYS reserves the right to change limits, conditions and dimensions.
© 2011 IXYS all rights reserved
Features / Advantages:
~A6
~E6
~K6
M1/O1
M10/O10
Applications:
● 3~ Rectifier with brake unit
Data according to IEC 60747and per diode unless otherwise specified
for drive inverters
W5
NTC
10
W
W6
10
U
S/T
S1
10
V
I
I
DAVM
FSM
RRM
Rectifier
3 ~
=
=
=
U1/
W1
1600
1100
188
A
A
V
VUB120-16NOXT
● Housing: V2-Pack
● DCB ceramic base plate
● Isolation voltage 3600 V~
● Easy to mount with two screws
● Space and weight savings
● RoHS compliant
Package:
V
I
V
C25
CES
CE(sat)
Chopper
Brake
=
=
=
1200
155
1.9
V
V
A
20111102a

Related parts for VUB120-16NOXT

VUB120-16NOXT Summary of contents

Page 1

... IXYS reserves the right to change limits, conditions and dimensions. © 2011 IXYS all rights reserved W5 W6 M1/O1 NTC ~A6 ~E6 ~K6 M10/O10 Applications: ● 3~ Rectifier with brake unit for drive inverters Data according to IEC 60747and per diode unless otherwise specified VUB120-16NOXT 3 ~ Brake Rectifier Chopper V = 1600 1200 V RRM CES I = 188 ...

Page 2

... Hz), sine t = 8,3 ms; (60 Hz), sine ms; (50 Hz), sine t = 8,3 ms; (60 Hz), sine ms; (50 Hz), sine t = 8,3 ms; (60 Hz), sine V = 400 MHz R Data according to IEC 60747and per diode unless otherwise specified VUB120-16NOXT Ratings min. typ. max 25°C 1700 25°C 1600 ...

Page 3

... RRM 600 V R -di /dt = 400 A/µ Data according to IEC 60747and per diode unless otherwise specified VUB120-16NOXT Ratings min. typ. max. Unit = 25°C 1200 V ± ±30 = 25°C 155 A = 80°C 107 A = 25°C 500 W = 25° ...

Page 4

... Prod. line Marking on Product VUB120-16NOXT Similar Part Package VUB120-16NOX V2-Pack Data according to IEC 60747and per diode unless otherwise specified VUB120-16NOXT Ratings min. typ. -40 - 3600 3000 6.0 12.0 Delivery Mode Quantity Code No ...

Page 5

... Outlines IXYS reserves the right to change limits, conditions and dimensions. © 2011 IXYS all rights reserved VUB120-16NOXT Marking ~A6 ~E6 ~K6 Data according to IEC 60747and per diode unless otherwise specified M1/O1 NTC U1/ W1 M10/O10 20111102a ...

Page 6

... T [° [K/W] 1 0.015 2 0.195 3 0.56 4 0.23 0 [s] Data according to IEC 60747and per diode unless otherwise specified VUB120-16NOXT 10000 RRM T =45° 1000 [ms] 2 Fig versus time per diode 200 ...

Page 7

... I [A] C Fig. 5 Typ. switching energy versus collector current 0.05 2 0.035 3 0.12 4 0.045 0 [s] Data according to IEC 60747and per diode unless otherwise specified VUB120-16NOXT 200 160 120 125° 25°C VJ ...

Page 8

... F Fig. 5 Typ. recovery time t vs. - [K/W] 1 0.465 0.0052 2 0.179 0.0003 3 0.256 0.0397 [s] Data according to IEC 60747and per diode unless otherwise specified VUB120-16NOXT [ 125° 800 V ...

Related keywords