RM1500DC-66F Powerex Inc, RM1500DC-66F Datasheet
RM1500DC-66F
Specifications of RM1500DC-66F
Related parts for RM1500DC-66F
RM1500DC-66F Summary of contents
Page 1
... RM1500DC-66F N/A APPLICATION Traction drives, High Reliability Converters / Inverters, DC choppers OUTLINE DRAWING & CIRCUIT DIAGRAM HVDi (High Voltage Diode) MODULES MITSUBISHI HVDi MODULES RM1500DC-66F HIGH POWER SWITCHING USE INSULATED TYPE ● I ……………………… 1500 A F ● ...
Page 2
... T = 125°C j Inductive load T = 150° 25°C j (Note 125° 150°C j MITSUBISHI HVDi MODULES RM1500DC-66F HIGH POWER SWITCHING USE INSULATED TYPE Ratings Unit 3300 V 3200 3300 V 3200 1500 A 3000 A 14 980 kA s 6000 ...
Page 3
... D = 100 µm, 1/2 module (c-f) Conditions M8: Main terminals screw M6: Mounting screw 1/2 module T = 25°C, 1/2 module c ) does not exceed dt. F MITSUBISHI HVDi MODULES RM1500DC-66F HIGH POWER SWITCHING USE INSULATED TYPE Limits Unit Min Typ Max — — 16.0 K/kW — 17.5 — K/kW Limits Unit ...
Page 4
... REVERSE RECOVERY CHARACTERISTICS Inductive load 3 125°C 2.5 2 1 500 5000 6000 MITSUBISHI HVDi MODULES RM1500DC-66F HIGH POWER SWITCHING USE INSULATED TYPE (TYPICAL) = 1800V 100nH 150° 125°C 1000 1500 2000 2500 3000 Forward Current [A] HVM-2023 ...
Page 5
... Tj = 125°C 10 10000 Z − [K/kW τ [sec MITSUBISHI HVDi MODULES RM1500DC-66F HIGH POWER SWITCHING USE INSULATED TYPE (TYPICAL) V ≤ 2500V, di/dt < 9kA/µ 150° 1000 2000 3000 Reverse Voltage [V] ⎧ ⎫ ⎛ ⎞ t ⎜ ...