PM2002 Sames, PM2002 Datasheet

no-image

PM2002

Manufacturer Part Number
PM2002
Description
Energy Meter Evaluation Module
Manufacturer
Sames
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PM2002DP
Manufacturer:
Semikron
Quantity:
1 000
Neutral
Application Note:
Energy Meter Evaluation Module
INTRODUCTION
This application note describes the functionality of the
SA2002D metering integrated circuit using the PM2002DP
evaluation module.
The SA2002 enables the meter manufacturer to build a meter
that measures the energy consumption, and records it to a
mechanical counter. Energy flow direction as well as energy
metering activity is indicated by means of LEDs. This
application note will focus on the practical use of the SA2002D,
more detailed information specific to the SA2002D can be
found in the applicable datasheet.
THE SA2002D PIN PROGRAMMABLE MONOCHIP
METER
SPEC-0088 (REV. 1)
Live In
PM2002DP
10A / 220V
20A / 220V
30A / 220V
40A / 220V
60A / 220V
80A / 220V
SA2002D. Pin status 0 indicates connection to VSS and 1
6A / 220V
Table 1: A summary of the pin settings possible with the
Setting
LED imp/kWh
Calibrated
indicates connection to VDD.
6400
6400
3200
3200
1600
1600
800
Figure 1: Connection and jumper settings for 80A / 220V bi-directional meter module
Pin Status
R0 = 0, R1 = 0, R2 = 1
R0 = 0, R1 = 0, R2 = 0
R0 = 1, R1 = 0, R2 = 0
R0 = 1, R1 = 0, R2 = 1
R0 = 0, R1 = 1, R2 = 0
R0 = 0, R1 = 1, R2 = 1
R0 = 1, R1 = 1, R2 = 0
1/10
CONNECTORS ON MODULE
The PM2002DP module connects directly to live and neutral
on SCK1. The module is referenced to live and should be kept
in mind when connecting test equipment to the module. The
current is measured by the shunt on the top of the PCB. The left
terminal of the shunt is connected to live. The live out will be
connected to the right terminal of the shunt.
Name
SCK1
JP2
JP3
Function Description
Mains connector for module power and voltage
sense
Optional current transformer connector.
(Underneath shunt resistor)
Optional Stepper motor connector. (Remove jumper
J6 to disconnect impulse counter)
Table 2: Connector descriptions
sames
sames
Live Out
08-11-00

Related parts for PM2002

PM2002 Summary of contents

Page 1

... Figure 1: Connection and jumper settings for 80A / 220V bi-directional meter module SPEC-0088 (REV. 1) CONNECTORS ON MODULE The PM2002DP module connects directly to live and neutral on SCK1. The module is referenced to live and should be kept in mind when connecting test equipment to the module. The current is measured by the shunt on the top of the PCB. The left terminal of the shunt is connected to live ...

Page 2

... PM2002DP MODULE SETUP The PM2002DP module is setup for use with the SA2002D integrated circuit. Resistor values used on the module are calculated for rated conditions of 80A/220V. Vdd Vss Vdd J11 Vss Vdd J12 Vss Vdd J13 Vss J14 Vdd Vss J15 Name ...

Page 3

... PM2002DP ANALOG SECTION The analog (metering) interface described in this section is designed for measuring 220V/80A with precision better than Class 1. The most important external components for the SA2002D integrated circuit are the current sense resistors, the voltage sense resistors and the bias setting resistor. The resistors used in the metering section should be of the same type so temperature effects are minimized ...

Page 4

... PM2002DP CT TERMINATION RESISTOR Provision is made for the use of a current transformer on the module. The existing shunt needs to be removed and the current sense resistors will have to be recalculated for the specific current transformer. The voltage drop across the CT termination resistor at rated current should be at least 20mV. ...

Page 5

... PM2002DP COMPONENT LISTS The following component list covers all components fitted on the PM2002DP module as shipped Symbol Description U1 SA2002D D1, D2 Diode, Silicon, 1N4007 D3, D4 Diode, Zener, 2.4V R1, R3 Resistor, 47k, 1/4W, 1%, metal Resistor, 150k, 1/4W, 1%, metal R2, R15 Resistor, 100R, 1/4W, 1%, metal R4, R5 Resistor, 1.6k, 1/4W, 1%, metal R6, R7 Resistor, 2.4k, 1/4W, 1%, metal ...

Page 6

... PM2002DP R10 N NEUTRAL SCK1 LIVE IN R14 SA IIN SB IIP VDD R13 C6 NEUTRAL LO LIVE OUT VSS J11 Figure 6: Schematic diagram of the complete PM2002DP module http://www.sames.co. IIN R7 2 IIP 3 VREF DIRO ...

Page 7

... PM2002DP PCB LAYOUT http://www.sames.co.za Figure 7: Top layer layout of the PM2002D module Figure 8: Bottom layer layout of the PM2002D module 7/10 sames sames ...

Page 8

... PM2002DP http://www.sames.co.za Figure 9: Silkscreen of the PM2002D module 8/10 sames sames ...

Page 9

... PM9607AP PM2002DP NOTE: http://www.sames.co.za 9/10 sames sames sames sames ...

Page 10

... PM2002DP PM9607AP DISCLAIMER: The information contained in this document is confidential and proprietary to South African Micro-Electronic Systems (Pty) Ltd ("SAMES") and may not be copied or disclosed to a third party, in whole or in part, without the express written consent of SAMES. The information contained herein is current as of the date of publication; however, delivery of this document shall not under any circumstances create any implication that the information contained herein is correct as of any time subsequent to such date ...

Related keywords