Clearing/Setting E1/T1 Framer Loopbacks: temuxLoopFramer
(TEMUX/TECT3 only)
This function clears or sets loopbacks within the E1/T1 framer section of the device. It is up to
the user to perform any tests on the looped data.
Clearing/Setting MX12 Devices Loopbacks: temuxLoopMX12
This function clears or sets loopbacks within the MX12 section of the device. It is up to the user
to perform any tests on the looped data.
Prototype
Inputs
Outputs
Returns
Valid States
Side Effects
Prototype
Inputs
Outputs
INT4 temuxLoopFramer (sTMX_HNDL devId, UINT2
frNum, TMX_LOOP_TYPE loop, BOOLEAN enable)
devId
enable
frNum
loop
None
Success =
Failure =
ACTIVE, INACTIVE
May inhibit the flow of active data
INT4 temuxLoopMX12 (sTMX_HNDL devId, UINT2
mxNum, UINT2 ds0Num, UINT2 up, BOOLEAN ais)
devId
mxNum
ds0Num
up
ais
None
TMX_ERR_RANGE
TMX_ERR_CLOSED
TMX_ERR_INVALID
TMX_ERR_NOTREADY
TMX_ERR_ISPRESENT
TMX_ERR_ISTEMAP
TMX_ERR_ADDR
TMX_ERR_HNDL
TMX_OK
TEMUX/TEMAP/TECT3 (PM8315, PM5365, PM4328) Driver Manual
: device handle (from
: clears loop if clear, else sets loop
: framer number (1-28 T1), (1-21 E1)
: loop type:
: device handle (from
: framer number (1-7)
: channel number (1-4)
: up/down flag
: add AIS when looping up flag
TMX_NOLOOP
TMX_DLOOP
TMX_LLOOP
TMX_PLOOP
temuxAdd
temuxAdd
Application Programming Interface
)
)