PART NUMBER: VSD-500
Features
·Protections: Short circuit/Over load/
·2000VAC I/O isolation
·Forced air cooling by built-in DC fan with speed
·100% full load burn-in test
·Built-in remote On-Off control
·Built-in remote sense function
·Output OK signal
·VSD-500L type input voltage design refers to
·3 year warranty
Over voltage/ Over temperature
control
LVD
20050 SW 112
Notes:
Model 1,3
VSD-500L-12
VSD-500L-24
VSD-500L-48
VSD-500H-12
VSD-500H-24
VSD-500H-48
1 All parameters Not specifically mentioned are measured at 48VDC and 96VDC input, rated load and 25ºC
2 Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uF
3 The power supply is considered a component which will be installed into final equipment. The final equipment
ambient temp.
& 47uF parallel capacitor.
must be re-confirmed that it still meets EMC directives.
th
Ave. Tualatin, Oregon 97062
72~144V DC
72~144V DC
72~144V DC
19~72V DC
19~72V DC
19~72V DC
Voltage
Input
Voltage
12V DC
24V DC
48V DC
12V DC
24V DC
48V DC
Output
phone
phone 503.612.2300 fax
Current
Output
10.5 A
10.5 A
40 A
21 A
40 A
21 A
DESCRIPTION: dc-dc converter
& Noise
150mV
150mV
150mV
150mV
150mV
150mV
Ripple 2
fax 503.612.2382
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
Load
Regulation
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
Line
Efficiency
rev.
rev.
page
page
date
date
85%
88%
89%
86%
89%
90%
04/2008
1 of 6

Related parts for VSD-500

VSD-500 Summary of contents

Page 1

... Over voltage/ Over temperature ·2000VAC I/O isolation ·Forced air cooling by built-in DC fan with speed control ·100% full load burn-in test ·Built-in remote On-Off control ·Built-in remote sense function ·Output OK signal ·VSD-500L type input voltage design refers to LVD ·3 year warranty Input Model 1,3 Voltage VSD-500L-12 19~72V DC ...

Page 2

... PART NUMBER: VSD-500 Input Voltage Parameter Conditions/Description Input voltage L H Output Parameter Conditions/Description DC Voltage adj. Over Voltage 12V Protection 24V 48V DC output power 12V 24V 48V Voltage Tolerance includes set up tolerance, line and load regulation. Hold up time Set up Protection Circuit Parameter ...

Page 3

... PART NUMBER: VSD-500 General and Safety Parameter Conditions/Description Operating temp. (refer to output derating curve) Storage temp. Operating humid. Non-condensing Storage humid. Non-condensing Temperature coefficient EMI EN55022(CISPR22) CLASS B Safety (EMC) En61000-4- ENV50204 light industry level, criteria A. IEC60950-1 CB approved by TUV Vibration ...

Page 4

... PART NUMBER: VSD-500 th 20050 SW 112 Ave. Tualatin, Oregon 97062 DESCRIPTION: dc-dc converter phone phone 503.612.2300 fax fax 503.612.2382 rev page 04/2008 date ...

Page 5

... PART NUMBER: VSD-500 th 20050 SW 112 Ave. Tualatin, Oregon 97062 DESCRIPTION: dc-dc converter phone phone 503.612.2300 fax fax 503.612.2382 rev page 04/2008 date ...

Page 6

... PART NUMBER: VSD-500 only for VSD-500L-12 th 20050 SW 112 Ave. Tualatin, Oregon 97062 DESCRIPTION: dc-dc converter for VSD-500L phone 503.612.2300 fax phone fax 503.612.2382 rev page 04/2008 date for VSD-500H ...