HS1E-40R IDEC Corporation, HS1E-40R Datasheet - Page 4

no-image

HS1E-40R

Manufacturer Part Number
HS1E-40R
Description
Hs1e Series Full Size Solenoid Locking Switches
Manufacturer
IDEC Corporation
Datasheet
Door Interlock Switches
HS1E-4 (Main Circuit: 1NC-1NC, Auxiliary Circuit: 1NO/1NO)
HS1E-14 (Main Circuit: 1NC-1NC, Auxiliary Circuit: 1NO)
Switch/Door
Status
Door
Circuit
Diagram
Main Circuit
Aux. Circuit
Solenoid
Switch/Door
Status
Door
Circuit
Diagram
Main Circuit
Aux. Circuit
Solenoid
1. Main Circuit: used to enable the machine to start only when the main circuit is closed.
2. Auxiliary Circuit: used to indicate whether the machine circuit or door is open or closed.
3. Terminals 7 and 8 are used for the LED indicator, and are isolated from solenoid and door status.
Contacts are linked to
the solenoid mechanically
Contacts are linked to
the solenoid mechanically
Door Closed
Machine ready to operate
Solenoid de-energized
Door Closed
Machine ready to operate
Solenoid de-energized
5-6: Power OFF
5-6: Power OFF
3-4: Closed
3-4: Closed
1-2: Open
1-2: Open
Status 1
Status 1
Door Closed
Machine cannot be started
Solenoid de-energized
Door Closed
Machine cannot be started
Solenoid energized
Contacts are linked to
the solenoid mechanically
Application Examples and Circuit Diagrams
Contacts are linked to
the solenoid mechanically
5-6: Power ON
5-6: Power ON
USA: 800-262-IDEC
1-2: Closed
3-4: Open
3-4: Open
1-2: Open
Status 2
Status 2
Door Opened
Machine cannot be started
Solenoid energized
Door Opened
Machine cannot be started
Solenoid energized
Contacts are linked to
the solenoid mechanically
Contacts are linked to
the solenoid mechanically
5-6: Power ON
5-6: Power ON
Canada: 888-317-IDEC
1-2: Closed
1-2: Closed
3-4: Open
3-4: Open
Status 3
Status 3
Door Opened
Machine cannot be started
Solenoid de-energized
Door Opened
Machine cannot be started
Solenoid de-energized
Contacts are linked to
the solenoid mechanically
Contacts are linked to
the solenoid mechanically
(Note)
5-6: Power OFF
5-6: Power OFF
3-4: Closed
1-2: Closed
1-2: Closed
3-4: Open
Status 4
Status 4
HS1E Series
Door Closed
Machine cannot be started
Solenoid de-energized
Door Closed
Machine cannot be started
Solenoid de-energized
Contacts are linked to
the solenoid mechanically
Unlocked Manually
Contacts are linked to
the solenoid mechanically
Unlocked Manually
5-6: Power OFF
5-6: Power OFF
1-2: Closed
3-4: Open
3-4: Open
1-2: Open
387