NOTES
(1) All parameters measured at Tc=25 °C, nominal input voltage and full
(2) Noise measurement bandwidth is 0-20 MHz for peak-peak
(3) Optimum performance is obtained when this power supply is operated
(4) Output regulation is specified by simultaneously changing from minimum
(5) Cross regulation is defined as the change in one output when the other
(6) Short term stability is specified after a 30-minute warmup at full load,
DGP20 Series Application Notes:
External Capacitance Requirements:
No external capacitance is required for operation of the DGP20
Series. However, for maximum performance, it is recommended that
the DGP20 Series use a capacitor of sufficient ripple current capacity
connected across the input pins if a capacitive input source is farther
than 1” from the converter. To meet the reflected ripple requirements
of the converter, an input impedance of less than 0.09 Ohms from at
220 kHz is required. External output capacitance is not required for
operation, however it is recommended that 1 μF to 10 μF of tantalum
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
FEB 27, 2006 revised to MAR 21, 2007
rated load unless otherwise noted.
measurements, 10 kHz to 1 MHz for RMS measurements. Output noise
is measured with a 1 μF tantalum located 1" away from the converter to
simulate PCB standard decoupling. Input reflected ripple is measured
into a 1 μH source impedance.
within the minimum to maximum load specifications.
to maximum load and noting the change in each output.
output is changed from full load to 25% of full load. The converter can be
run at no load on either or both outputs with no damage.
constant line and recording the drift over a 24-hour period.
DGP20 Triple-Output DC-DC Series Data Sheet
Page 3 of 4
and 0.001 to 0.1 μF ceramic capacitance be selected for reduced
system noise. Additional output capacitance may be added for
increased filtering, but should not exceed 400 μF.
Remote On/Off Operation:
The remote On/Off pin may be left floating if this function is not used.
It is recommended to drive this pin with an open collector/drain or a
relay contact. When the On/Off pin is pulled low with respect to the
-INPUT, the converter is placed in a low power drain state. The input
capacitors are kept fully charged in the OFF mode. For proper
operation, do not drive this input from a logic gate directly. The On/Off
pin should never be pulled more than 0.3 volts below -INPUT or have
a voltage greater than +8 volts applied.