CMH05MT900 Viking Tech Corporation, CMH05MT900 Datasheet - Page 5

no-image

CMH05MT900

Manufacturer Part Number
CMH05MT900
Description
Chip Common Mode Choke? ?? ?cm Series
Manufacturer
Viking Tech Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CMH05MT900
Manufacturer:
VIKING/光颉
Quantity:
20 000
■ ■ ■ ■ Environmental Characteristics
Electrical Performance Test
Mechanical Performance Test
Climatic Test
Tel:886-3-5972931
Impedance
DC Resistance DCR
Withstand Voltage (VDC)
Rated Voltage (VDC)
Insulation Resistance (I.R)
Component Adhesion
(Push Test)
Drop
Solderability
Vibration Test (Low Frequency)
Low Temperature Storage
Thermal Shock
High Temperature Storage
Humidity
High Temperature Load Life
Low Temperature Load Life
Storage Temperature: 25±3° C; Humidity < 80%RH
Items
Items
Items
Fax: 886-3-5973494
Component should not be damaged
Base: 0805≧2 Lbs
Cover: 0805≧1 Lbs
Base: 1206≧4 Lbs
Component should not be damaged
The terminal should at least be 90%
covered with solder
Component should not be damaged
Refer to standard electrical
Cover: 1206≧2 Lbs
Impedance change: Within± 20%
Without distinct damage in appearance
There should be no evidence of short or
open circuit
characteristic spec.
Requirement
Requirement
Requirement
E-mail:
sales@viking.com.tw
LCR Meter HP 4291B
Micro-Ohm meter (GOM-801G)
Test Voltage: 2.5 Times Rated Voltage
Testing Time: 60 seconds
Charge Current: 0.5mA
Test Voltage: Rated Voltage
Testing Time: 1 to 5 seconds
Charge Current: 1mA
Charge Current: 1minute
10M ohm min.
The component should be soldered (232°C ± 5°C for 10 sec.) to
tinned copper substrate
Applied force gauge to the side of component It must withstand
force of 2 or 4 pounds without failure of the component.
Dropping chip by each side and corner. Drop 10 times in total
Drop height: 100 cm
Drop weight: 125 g
The component shall be dipped in a melted solder bath at 245
±5°C for 3 seconds
4. Duration: 2 Hrs/X, Y, Z
1. Temp: -40 ±2°C
2. Time: 1000±48 Hours
3. Component should be tested after 1hour at room temperature
1. Temp: 85 ± 2°C
2. Time: 1000 ± 48 Hours
3. Component should be tested after 1hour at room temperature
1. Temp: 40 ± 2°C
2. R.H. : 90 ~ 95%
3. Time: 48 ±2 Hours
1. Temp: 85 ± 2°C
2. Time: 96 ± 12 Hours
3. Load: Allowed DC Current
1. Temp: -40 ± 2°C
2. Time: 96 ± 12 Hours
3. Load: Allowed DC Current
1. Amplitude: 1.5 m/m
2. Frequency: 10-55-10Hz (1min.)
3. Direction: X, Y, Z
Total: 5 Cycles
ROOM TEMP
ROOM TEMP
15MINS
15MINS
http://www.viking.com.tw
Test Conditions / Test Methods
Test Conditions / Test Methods
Test Conditions / Test Methods
30MINS
-25 ±2℃
85±2℃
30MINS
129

Related parts for CMH05MT900