TL02UO Communications & Power Industries, Inc., TL02UO Datasheet - Page 2

no-image

TL02UO

Manufacturer Part Number
TL02UO
Description
250w Superlinear Outdoor Buc For Satellite Communications
Manufacturer
Communications & Power Industries, Inc.
Datasheet
• Remote Control Panel
• Extended Frequency:
• Redundant and Power
• External Receive Band
• Integrated 1:1 switch
• Integral Linearizer
• Remove BUC - contact CPI
For more detailed information, please refer to the corresponding CPI Technical Description.
Note: Specifi cations may change without notice as a result of additional data or product refi nement.
Please contact CPI before using this information for system design.
MKT 214L, ISSUE 3
Ku - Ba nd
up to 12.7 GHz)
O P T I O N S :
13.75-14.50 GHz; 12.75-
13.25 GHz)
Combined Subsystems
Reject Filter (Increases
loss by a minimum 60 dB
control and drive
for details on specifi cations
03/10
Certificate Number: 30515
PDF
SPECIFICATIONS, TL02UO BUC
Electrical
Frequency
Output Power
*Note: This amplifi er does not provide 220 W of power at the fl ange. The
Flange Peak Power specifi cation is provided so that the user can more
easily calculate the desired backoff level from peak.
Bandwidth
Gain
Gain Stability
Small Signal Gain Slope
Small Signal Gain Variation
RF Level Adjust Range
Input VSWR
Output VSWR
Load VSWR
MUXed External 10 MHz
Reference Phase Noise
Required (L-Band Input
950 - 1450 MHz)
Single Sideband Phase Noise -63 dBc at 100 Hz offset
Spurious
AM/PM Conversion
Harmonic Output
Noise Power Density
(at maximum gain)
CW (Linear) power at fl ange 40 W min. (46.0 dBm)
CW (Linear) at fl ange (max)
TWT Peak Power
Flange Peak Power*
950 MHz to 1450 MHz (input)
14.0 to 14.5 GHz (output)
250 W min. (53.98 dBm)
220 W min. (53.42 dBm)
(80 W min. with linearizer)
50 W (100 W with linearizer)
500 MHz
60 dB min. at rated power output;
64 dB typ. at small signal
±0.25 dB/24hr max.
(at constant drive and temp.)
±0.04 dB/MHz max.
1.0 dB pk-pk across any 80 MHz band;
3.0 dB pk-pk across the 500 MHz band
30 dB typ.
1.3:1 max.
2.2:1 max.
2.0:1 max. continuous operation; any value for
operation without damage
-115 dBc/Hz at 10 Hz
-140 dBc/Hz at 100 Hz
-145 dBc/Hz at 1 kHz
-150 dBc/Hz at ≥10 kHz
(Level -3 to +7 dBm)
-73 dBc at 1 kHz offset
-83 dBc at 10 kHz offset
-93 dBc at 100 kHz offset
-103 dBc at 1 MHz offset
-113 dBc at ≥10 MHz offset
-60 dBc max. at 100 W output
2.0°/dB max. for a single carrier up to 100 W
-60 dBc max. at 100 W output
<-150 dBW/4 kHz, below 12.7 GHz
<-66 dBW/4 kHz, passband to 18.0 GHz
Electrical (continued)
Intermodulation
Primary Power
Power Consumption
Power Factor
Environmental (Operating)
Ambient Temperature
Relative Humidity
Altitude
Shock
Vibration
Acoustic Noise
Mechanical
Cooling
L-Band Input Connection
RF Output Connection
RF Output Monitor
Dimensions (W x H x D)
Weight
-25 dBc max. with respect to the
sum of both carriers at total output
power of 100 W
100-240 VAC ±10% single phase,
47-63 Hz
550 VA max.
500 VA typ. at 100 W output power
300 VA typ. at 1 W output power
0.95 min.
-40°C to +60°C operating,
-40°C to +71°C non-operating
100% condensing
10,000 ft. with standard adiabatic
derating of 2°C/1000 ft., operating;
50,000 ft., non-operating
20 g pk, 11 mS, 1/2 sine
3 g
65 dBA @ 3 ft. from amplifi er
Forced air with integral blower
Type N female
WR-75 waveguide fl ange,
grooved with UNC 2B 6-32
threaded holes
Type N female, 44 dB nom.
8.5 x 8.5 x 15 in. max.
(216 x 216 x 381 mm)
25 lbs (11.4 kg) typ
rms
including solar loading;

Related parts for TL02UO