3.Characteristics
www.shoulder.cn Tel:0755-82916880 Fax:0755-82916881 E-mail:info@shoulder.cn
SAW FILTER
2.2. Circuit construction, measurement circuit
3.1 Maximum Rating
Standard
atmospheric
conditions
Operating
temperature rang
Storage
temperature rang
Reference
temperature
DC voltage
AC voltage
Items
Unless otherwise specified , the standard rang of
atmospheric conditions for making
measurements and tests is as follows;
Operating temperature rang is the rang of ambient
temperatures in which the filter can be
operated continuously. -10℃ ~ +60℃
Storage temperature rang is the rang of ambient
temperatures at which the filter can be stored
without damage.
Conditions are as specified elsewhere in these
specifications. -40℃ ~ +70℃
+25℃
VDC
Vpp
Ambient temperature
Relative humidity
Air pressure
12
10
Conditions
: 86kPa to 106kPa
: 15℃ to 35℃
: 25% to 85%
V
V
HDBF44A3Dc SIP5Dc
Between any terminals
Between any terminals
There shall be no
Specifications
damage.