V300A Vicor Corporation, V300A Datasheet - Page 2

no-image

V300A

Manufacturer Part Number
V300A
Description
Dc-dc Converter Module
Manufacturer
Vicor Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
V300A12C400
Manufacturer:
FUJI
Quantity:
1 000
Part Number:
V300A12C500A
Manufacturer:
VICOR
Quantity:
84
Part Number:
V300A12C500A2
Manufacturer:
VICOR
Quantity:
84
Part Number:
V300A12C500A3
Manufacturer:
VICOR
Quantity:
84
Part Number:
V300A12C500AL
Manufacturer:
VICOR
Quantity:
84
Part Number:
V300A12C500AL
Manufacturer:
VICOR
Quantity:
20 000
Part Number:
V300A12C500AL
Quantity:
60
Part Number:
V300A12C500BL
Manufacturer:
VICOR
Quantity:
20 000
Part Number:
V300A12H500BL
Manufacturer:
VICOR
Quantity:
20 000
Part Number:
V300A12M500AL
Manufacturer:
VICOR
Quantity:
20 000
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature,
unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate.
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20265)
Baseplate to ambient
Baseplate to ambient; 1000 LFM
Thermal capacity
2 V
3.3 V
5 V
8 V
12 V
15 V
24 V
28 V
36 V
48 V
For important information relative to applications where the converter modules are subject to continuous dynamic loading, contact Vicor applications
engineering at 800-927-9474.
Set your site on VICOR at www.vicorpower.com
147.4
180
10
±0.002
174.6
152.8
±0.02
300
± 2
-0.5 to 10.9
-0.5 to 16.1
-0.5 to 20.0
-0.5 to 31.7
-0.5 to 36.9
-0.5 to 47.4
-0.5 to 62.9
-0.5 to 3.1
-0.5 to 4.7
-0.5 to 7.0
±0.005
178.2
±0.20
375
400
110
± 5
±1
300V Maxi Family
% Vout nom.
0.08
0.07
165
4.9
1.1
% / °C
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
%
%
%
<100 ms
Not included
Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Watt-sec/°C
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Rev. 8.3
Page 2 of 13

Related parts for V300A