STLM75 STMicroelectronics, STLM75 Datasheet - Page 21
![no-image](/images/manufacturer_photos/0/6/637/stmicroelectronics_sml.jpg)
STLM75
Manufacturer Part Number
STLM75
Description
Digital Temperature Sensor And Thermal Watchdog
Manufacturer
STMicroelectronics
Datasheet
1.STLM75.pdf
(37 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STLM75DS2E
Manufacturer:
ST
Quantity:
20 000
Part Number:
STLM75DS2F
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
STLM75M2E
Manufacturer:
AT&T
Quantity:
6 218
Part Number:
STLM75M2E
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
STLM75M2F
Manufacturer:
STMicroelectronics
Quantity:
1 850
Part Number:
STLM75M2F
Manufacturer:
ST
Quantity:
20 000
3.4.4
Data valid
The state of the data line represents valid data when after a start condition, the data line is
stable for the duration of the high period of the clock signal. The data on the line may be
changed during the Low period of the clock signal. There is one clock pulse per bit of data.
Each data transfer is initiated with a start condition and terminated with a stop condition.
The number of data bytes transferred between the start and stop conditions is not limited.
The information is transmitted byte-wide and each receiver acknowledges with a ninth bit.
By definition a device that gives out a message is called “transmitter”, the receiving device
that gets the message is called “receiver”. The device that controls the message is called
“master”. The devices that are controlled by the master are called “slaves”.
Figure 6.
CLOCK
DATA
CONDITION
Serial bus data transfer sequence
START
DATA VALID
DATA LINE
STABLE
DATA ALLOWED
CHANGE OF
CONDITION
STOP
AI00587