NET-35 Mean Well Enterprises Co., Ltd., NET-35 Datasheet

no-image

NET-35

Manufacturer Part Number
NET-35
Description
35w Triple Output Switching Power Supply
Manufacturer
Mean Well Enterprises Co., Ltd.
Datasheet
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 6)
OTHERS
NOTE
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
OUTPUT NUMBER
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
EMI CONDUCTION & RADIATION
35W Triple Output Switching Power Supply
Note.6
Note.4
Note.5
Note.3
Note.2
NET-35A
5V
3A
0.5 ~ 4A
29.5W
80mVp-p
CH1:4.75 ~ 5.5V
CH1
500ms, 30ms/230VAC
50ms/230VAC
85 ~ 264VAC
47 ~ 63Hz
0.36Kg; 45pcs/17.2Kg/0.93CUFT
78%
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover
-20 ~ +60
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CB(IEC60950-1) Approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1 Light industry level, criteria A
386.2Khrs min.
99*97*36mm (L*W*H)
0.75A/115VAC
COLD START 45A
<2mA / 240VAC
2.0%
0.5%
1.5%
0.03%/
CH2
12V
1A
0.1 ~ 1.5A 0.1 ~ 0.5A
120mVp-p 120mVp-p
(0 ~ 45 )
6.0%
1.0%
3.0%
(Refer to output load derating curve)
120 ~ 370VDC
I/P-FG:1.5KVAC
MIL-HDBK-217F (25 )
10ms/115VAC at full load
CH3
-5V
0.5A
0.5A/230VAC
6.0%
1.0%
3.0%
1200ms, 30ms/115VAC at full load
NET-35B
CH1
5V
3A
0.5 ~ 4A
33W
80mVp-p
CH1: 4.75 ~ 5.5V
79%
2.0%
0.5%
1.5%
O/P-FG:0.5KVAC
CH2
12V
1A
0.1 ~ 1.5A 0.1 ~ 0.5A
120mVp-p 120mVp-p
6.0%
1.0%
3.0%
CH3
-12V
0.5A
6.0%
1.0%
3.0%
NET-35C
0.5 ~ 3.5A
CH1
5V
2.5A
35W
80mVp-p
CH1: 4.75 ~ 5.5V
79%
2.0%
0.5%
1.5%
CH2
15V
1A
0.1 ~ 1.5A 0.1 ~ 0.5A
150mVp-p 150mVp-p
8.0%
1.0%
3.0%
N E T- 3 5
CH3
-15V
0.5A
8.0%
1.0%
3.0%
NET-35D
File Name:NET-35-SPEC 2006-12-27
CH1
5V
2.5A
0.5 ~ 3.5A
36.5W
80mVp-p
CH1: 4.75 ~ 5.5V
79%
2.0%
0.5%
1.5%
0.1 ~ 1A
CH2
24V
0.5A
200mVp-p
8.0%
1.0%
3.0%
s e r i e s
CH3
12V
1A
0.1 ~ 1A
120mVp-p
8.0%
1.0%
3.0%

Related parts for NET-35

NET-35 Summary of contents

Page 1

... I/P-FG:1.5KVAC O/P-FG:0.5KVAC MIL-HDBK-217F ( NET-35C NET-35D CH3 CH1 CH2 CH3 CH1 -12V 5V 15V -15V 5V 0.5A 2.5A 1A 0.5A 2.5A 0.5 ~ 3.5A 0.1 ~ 1.5A 0.1 ~ 0.5A 0.5 ~ 3.5A 35W 36.5W 80mVp-p 150mVp-p 150mVp-p 80mVp-p CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V 6.0% 2.0% 8.0% 8.0% 2.0% 1.0% 0.5% 1.0% 1.0% 0.5% 3.0% 1.5% 3.0% 3.0% 1.5% 79% 79% File Name:NET-35-SPEC 2006-12- CH2 CH3 24V 12V 0. 200mVp-p 120mVp-p 8.0% 8.0% 1.0% 1.0% 3.0% 3.0% ...