DSPIC30F3011 Microchip Technology Inc., DSPIC30F3011 Datasheet - Page 39

no-image

DSPIC30F3011

Manufacturer Part Number
DSPIC30F3011
Description
Dspic30f3010/3011 Enhanced Flash 16-bit Digital Signal Controller
Manufacturer
Microchip Technology Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DSPIC30F3011-20E/PT
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
DSPIC30F3011-20I/PT
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
DSPIC30F3011-30I/ML
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
DSPIC30F3011-30I/P
Manufacturer:
Microchip
Quantity:
927
Part Number:
DSPIC30F3011-30I/PT
Manufacturer:
MICROCHIP
Quantity:
316
Part Number:
DSPIC30F3011-30I/PT
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
DSPIC30F3011-30I/PT
Manufacturer:
MICROCHI
Quantity:
20 000
Part Number:
DSPIC30F3011-30I/PT
0
Part Number:
DSPIC30F3011T-20E/PT
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
DSPIC30F3011T-20I/PT
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
DSPIC30F3011T-30I/PT
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
DSPIC30F3011T-30I/PT
0
4.2.1
The Modulo Addressing scheme requires that a
starting and an end address be specified and loaded
into the 16-bit Modulo Buffer Address registers:
XMODSRT, XMODEND, YMODSRT and YMODEND
(see Table 3-3).
The length of a circular buffer is not directly specified. It
is
corresponding start and end addresses. The maximum
possible length of the circular buffer is 32K words
(64 Kbytes).
FIGURE 4-1:
© 2007 Microchip Technology Inc.
Note:
Byte
Address
0x1100
0x1163
determined by the difference
START AND END ADDRESS
Y-space Modulo Addressing EA calcula-
tions assume word-sized data (LSb of
every EA is always clear).
Start Addr = 0x1100
End Addr = 0x1163
Length = 0x0032 words
MODULO ADDRESSING OPERATION EXAMPLE
between
MOV
MOV
MOV
MOV
MOV
MOV
MOV
MOV
DO
MOV
AGAIN: INC
Confidential
the
#0x1100,W0
W0, XMODSRT
#0x1163,W0
W0,MODEND
#0x8001,W0
W0,MODCON
#0x0000,W0
#0x1110,W1
AGAIN,#0x31
W0, [W1++]
W0,W0
4.2.2
The Modulo and Bit-Reversed Addressing Control
register MODCON<15:0> contains enable flags, as
well as a W register field to specify the W address
registers. The XWM and YWM fields select which
registers will operate with Modulo Addressing. If XWM
= 15, X RAGU and X WAGU Modulo Addressing are
disabled. Similarly, if YWM = 15, Y AGU Modulo
Addressing is disabled.
The X Address Space Pointer W register (XWM), to
which Modulo Addressing is to be applied, is stored in
MODCON<3:0> (see Table 3-3). Modulo Addressing is
enabled for X data space when XWM is set to any value
other than 15 and the XMODEN bit is set at
MODCON<15>.
The Y Address Space Pointer W register (YWM), to
which Modulo Addressing is to be applied, is stored in
MODCON<7:4>. Modulo Addressing is enabled for Y
data space when YWM is set to any value other than 15
and the YMODEN bit is set at MODCON<14>.
dsPIC30F3010/3011
;set modulo start address
;set modulo end address
;enable W1, X AGU for modulo
;W0 holds buffer fill value
;point W1 to buffer
;fill the 50 buffer locations
;fill the next location
;increment the fill value
W ADDRESS REGISTER
SELECTION
DS70141D-page 37