MTD502E ETC-unknow, MTD502E Datasheet - Page 15
MTD502E
Manufacturer Part Number
MTD502E
Description
2 Port 10m/100m Switch With Build_in Memory
Manufacturer
ETC-unknow
Datasheet
1.MTD502E.pdf
(20 pages)
63
65
66
67
68
69
71
Pin No.
IO
IO
IO
IO
IO
IO
IO
IO
MYSON
TECHNOLOGY
MTD502EG(80LQFP) Jumper Setting Table After Power On Reset
P1_CRCchk Disable
P0_CRCchk Disable
Setting Function
VLAN tag Enable
DeviceID[3]
DeviceID[2]
DeviceID[1]
DeviceID[0]
Jumper setting function after power on reset.
-external pull_high = 1.
-external pull_low = 0.
-external floating : default is 0.
Jumper setting function after power on reset.
-external pull_high = 1.
-external pull_low = 0.
-external floating : default is 0.
Jumper setting function after power on reset.
-external pull_high = 1.
-external pull_low = 0.
-external floating : default is 0.
Jumper setting function after power on reset.
-external pull_high = 1.
-external pull_low = 0.
-external floating : default is 0.
Jumper setting function after power on reset.
-external pull_high = 1, means Port1 CRC check and drop function
-external pull_low = 0, means Port1 CRC check and drop function
-external floating : default is 0.
Jumper setting function after power on reset.
-external pull_high = 1, means Port0 CRC check and drop function
-external pull_low = 0, means Port0 CRC check and drop function
-external floating : default is 0.
Jumper setting function after power on reset.
-external pull_high = 1, means MAC receiving accept 1522 Bytes
-external pull_low = 0, means MAC receiving reject 1522 Bytes
-external floating : default is 0.
15/20
is disabled.
is enabled.
is disabled.
is enabled.
packet (VLAN tag enable).
packet (VLAN tag disable).
Descriptions
MTD502E Revision 1.3 12/07/2000
MTD502E